Non Intrusive Video Capillary Microcirculation Microscope Clinic 10 Inch Blood Analysis Machine
|
Non-intrusive Video Clinic 10 Inch Blood Analysis Machine Capillary Microcirculation Microscope
Shape of blood vessel ansa : (1) Normal shape likes the hair clip , exceptionally for overlapping and abnormal, the overlapping proportion number should not surpass 30%, the abnormal should not surpass 10%. (2) abnormal blood vessel: Explained: 1st, the blood vessel of heart and brain disease, the diabetes, the desmosis and so on, with contract whole body disease or the partial fungus infection and flesh wound and other organization disease is easy to appear the blood vessel to be abnormal 2nd, when arteriosclerosis, diabetes with serious abnormal , and the proportion excessive highly. 3rd, collagen disease, Reynold sickness, neurosis, the variation of blood vessel increases.
Blood vessel ansa’s periphery After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition: 1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces. 2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside. Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on.
Testing conditions: 1) Check the room temperature and humidity. Room temperature and humidity should be kept relatively constant. room temperature should be maintained in the 22-24 degree , relative humidity about 70% 2) the patient generally take seats, keep the height of the hand the same with heart 3) Preparation of paraffin oil or cedar oil.Drop 2 drops in the nailfold skin. (Purpose prove light transmission, and reduce skin scattering) 4) Testing generally be in the morning or afternoon, and review should at the same time every day. 5) the patient should a. Avoiding intense activity or manual labor within one hour before testing b. Take a rest about 15-30 minutes before testing c. Can not take any drug which will affect the cardiovascular vessels before testing d. Does not smoke , wash hands or eat within an hour before testing e. Pay attention to the influence of the Female menstrual
Blood microcirculation: 1. Model GY-160(10inch color LCD)
What's micro circulation ? Microcirculation is the circulation of the blood in the smallest
blood vessels,present in the vasculature embedded within organ
tissues. This contrasts with macrocirculation, which is the
circulation of blood to and from the organs. Microcirculation is
composed of terminalarterioles, capillaries capillaries and venules
which drain capillary blood. The vessels on the arterial side of
the microcirculation are called the arterioles, which are well
innervated, are surrounded by smooth musclecells, and are 10-100 µm
in diameter. Microcirculation is usually very smooth, but by high blood lipids,
blood viscosity, erythrocyte aggregation, affect cardiovascular
disease and other factors, microcirculation appears white tiny
blood clots, which with the blood flow in the body. Once the blood vessels become thin, distorted and clog the blood
vessels (especially the elderly), there will be a corresponding
disease, ranging from dizziness, insomnia, dizziness, numb lips,
palpitation, chest tightness. If there is a large area of the brain
or heart blockage will cause hemiplegia, language barriers,
myocardial infarction. Therefore, early detection of thrombosis
should check the microcirculation by actively antithrombotic
thrombolysis, and clear the microcirculation, preventive measures.
Microcirculation is usually very smooth, but by high blood lipids,
blood viscosity, erythrocyte aggregation, affect cardiovascular
disease and other factors,microcirculation appears white tiny blood
clots, which with the blood flow in the body. Once the blood vessels become thin, distorted and clog the blood
vessels (especially the elderly), there will be a corresponding
disease, ranging from dizziness, insomnia, dizziness, numb lips,
palpitation, chest tightness. If there is a large area of the brain
or heart blockage will cause hemiplegia, language barriers, myocardial infarction. Therefore,
early detection of thrombosis should check the microcirculation by
actively antithrombotic thrombolysis, and clear the
microcirculation, preventive measures. Currently, the primary means of discovery is microcirculation
microcirculation microscopic examination instrument, and general
such as CT, MRI, X-ray, B-and so can not be found, so the clinical
microcirculation earlier than macroscopic examination has found
early diagnosis role. Meanwhile, health groups and immunocompromised people are mainly in
the microcirculation, lack of microvascular perfusion, vascular
blurred, slow blood flow. By detecting the microcirculation can
also quickly find the body in which the current situation in a
timely manner as soon as possible be microcirculation, increase
resistance and immunity, improve the sub-health conditions. The Nailfold Capillaroscopy Microcirculation Microscope is an
advance medical photoelectric apparatus,equipped with built in
special LED light source,used mainly in observation on human nail
fold capillary microcirculation or term as video Nailfold
capillaroscopy,Such as capillary blood flow, abnormal
microcirculation of the vascular structure, cell adhesion, through
its powerful 380X(or 240X)optical magnification. Undistorted, real
time dynamic video streaming via Sony CCD imaging device onto the
LCD monitor screen. Simply insert the finger to the holder below the optical lens
apparatus, fine-tune to fix the focal length and uncover the
desired images within seconds.Blood capilliary microcirculation
microscope is a non-invasive diagnostic tools, which is gaining
large credit among physicians of different specialities in for
study of skin blood capilliary network. After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition: 1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces. 2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside . Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on .
Technical parameters:
Features: 1. in 5 seconds can be observed in the microvascular circulation,
simple operation and fast;
Application: 1. nail wall distal microcirculation observation
Distributed pattern for finger nail fold blood capillary
The observation for nail fold micro circulation is mainly from three aspects ,including the shape, the fluid state and the blood vessel ansa perimeter. Normal state: Nail fold blood capillary arrangement neat, distribution even, the blood vessel ansa is clearly discernible. Abnormal state: Arrangement disorder, blood vessel ansa fuzzy, is possible to because of the oxygen deficit, the blood stream to be impeded, the Asian health and so on causes.
Packaging & Shipping
Service and Warranty |
||||||||||||||||
Product Tags: capillary microscope nail microscope |
![]() |
Non Intrusive Video Capillary Microcirculation Microscope Clinic 10 Inch Blood Analysis Machine |
![]() |
Detecting Body Health Microcirculation Microscope Color Screen Blood Test Machine |
![]() |
Portable Led Display Nail Fold Capillaroscopy Microscope 400x Magnification |
![]() |
Professional Biological Capillary Microscope Digital DC12V 2A Output GY-160 |
![]() |
LCD Digital Biological Microscope Microcirculation Checking Capillary Microscope |
![]() |
Blood Capillary Microcirculation Microscope 600X Magnification DC12V 2A Output |