Conference Hall Folding Sliding Movable Door Partitions Banquet
Acoustic Folding Room Partitions Finished Project 1. 2 sets of wall. Width: 30 meters. Height: 7.86 meters.We have
sent our engineer(Mr. Zeng) to Lebanon to supervise the
installation. 2. Finish: Melamine Surface.
The procedure of installing the acoustic partition walls 1. Please designate the responsible person before construction and
leave contact information to facilitate communication between the
two parties on construction logistics. 2. If the ground has been finished before the track construction,
if the carpet, floor tiles, floor, etc. have been laid, you need to
do ground protection to prevent the welding sparks from damaging
the ground. 3. You need to provide the height of the shed after the decoration
is completed. We will determine the height of the track
installation according to this height. 4. Because we need to calculate the size of the hanging track, you
need to provide the net size of the finished wall and the pillar.
We will hang the track according to this size. 5. After the track suspension is completed, the reserved wall size
given by you cannot be changed. Because we calculate the
construction according to this size, if the size is changed, the
door panel will not operate. 6. After the track suspension is completed, our construction
personnel will fill in the dimensional confirmation letter to
provide accurate data for the production of the wallboard. You need
to specify the person in charge of the site to confirm. 7. The acoustic partition walls should be horizontally
perpendicular to the ground directly below the track, and the error
should not exceed 1cm. 8. If there are other constructions at the same time, please do not
pierce the foreign objects such as nails and insert them on the
installed rails. This will cause the door pulleys to not run in the
track. 9. Each group of tracks will have a “raw mouth”, which will be
removed before installing the door panel, and then installed after
the door panel is installed. This "raw mouth" cannot be sealed. 10. In order to facilitate future maintenance and maintenance,
please reserve the inspection port near the ceiling track to
facilitate the maintenance personnel to enter the inspection port
for product maintenance and maintenance. 11. If you need to improve the sound insulation effect of the
product, after the track is hung, you can make sound insulation
between the track and the original shed. 12. After the door panel is hung, it needs to be debugged. Active
partition reminder Do not use the door panel before our personnel
have debugged the door panel, otherwise forcible use will result in
damage to the door panel.
Technical information Series | BG65 | BG85 | BG100 | Panel suspension | Top hung only | Top hung only | Top hung only | Panel thickness | 65mm | 85mm | 100mm | Max height | 4000mm | 6000mm | 18000mm | Panel width | 500-1200 mm | 500-1200 mm | 500-1200 mm | Face material | 9mm | 9mm | 12 mm | Pass doors | Single door or Double door | Sound insulation | 20-32dB Rw | 28-36dB Rw | 32-50dB Rw | Finish Material | Plywood, MDF, Laminate, Melamine, Gypsum board, Fabric, Leather,
Insulation board, Fireproof board, Wall paper, Vinyl, Painting,
etc. (Customized) |
|