Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810
|
ICP6810 in the nonferrous gold industry ●The ICP6810 profile is introduced ICP-6810 is Full spectrum direct reading inductively coupled plasma emission spectrometer for determining trace and trace element content in different substances (soluble in nitric acid, hydrochloric acid, hydrofluoric acid, etc.), which is widely used in environmental protection, petroleum products, rare earths, semiconductors, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.
Table 1. Main technical parameters of ICP6810 ●ICP6810 main technical parameters High frequency ionizer Working frequency 27.12MHz Frequency stability ﹤0.05% Output power 800W ~1600W Output power stability ≤0.05% OMatching way Automatic matching Scan the light divider light path Full reflection imaging light path, quartz prism two-dimensional dispersion system focal distance 400mm Graster specifications Middle step grating, 52.67, l p / mm, 64 shining angle Resolution ratio <0.0068nm@200nm Complete machine technical indicators Scan the wavelength range At 165-900nm, full wavelength coverage, and measurable Al 167.120nm Repetitiveness RSD≤1.5% Stability RSD≤2.0%
●ICP6810 element detection limit (g / L)
2. Precious metal sample test solution sample measureelement Analysis instrument Sample handling overview (for reference only) remarks Non-ferrous precious metal alloy Gold, silver, palladium, platinum, and so on ICP6810 Take 0.1-0.3g sample in a 100ml beaker, add 5ml hydrochloric acid, dissolve the sample on the heating plate to clarification, remove cold to room temperature, transferred to 50ml volumetric flask diluted with water to scale for testing. Sample blank experiment was also performed simultaneously duringthesampleprocessing process.
According to the configured standard solution concentration, directly on the computer test, the instrument can automatically give the final test results, and can be directly printed in the form of a report. Table 3.ICP6810 and related instrument configuration
Exhibition:
The Company: The Factory:
Contact Us: |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: faster detection speed cid detector 800w cid detector |
![]() |
Macylab Basic Uv Vis Instrument Uv-1300 4nm Spectral Bandwidth For Lab |
![]() |
Adjustable Bandwidth Double Beam Uv Spectrophotometer Import Silicon Photodiode |
![]() |
Six Lamps Automatic Switch Aas Spectrophotometer Flame And Graphite Furnace Double System |
![]() |
Testing Protein And Dna Micro Volume Uv Vis Spectrophotometer Compact |
![]() |
Macylab 4 Nm Portable Uv Vis Spectrophotometer Universal Uv-1300 |
![]() |
Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810 |