Geology Inductively Coupled Plasma Optical Emission Spectrophotometer Icp-6800
|
ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard) Application Field Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation. At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.
Application Environment CONTENT RANGE Shipping/Storage Ambient Temperature 15℃-25℃ Shipping/Storage Relative Humidity ≤70% Atmospheric pressure 86-106 kPa Power Supply 220±10V 50-60MHz Working Humidity ≤70% Working Temperature 15℃-30℃
RFPower technical parameter: Circuit type: solid-state RF power supply, with function of automatch Frequency: 27.12MHz±0.05% Frequency Stability: <0.1% Power Output: 800W—1200W Power Output Stability: <0.3% Escaped RF radiation: 30cm away from the instrument, electric field: E﹤2V/m
Sampling System Technical Parameter: Output working coil inner diameter :25mm Torque tube: Three concentric, external diameter 20mm Coaxial nebulizer:Outer diameter 6mm Double barrel atomizing chamber: Outer diameter 34mm
Gas Flow Controls 1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min) 2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min) 3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min) 4.Pressure Maintaining Valve(0-0.4MPa) 5.Cooling Water:Temperature: 20-25℃, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa
Spectrometer Optics:Czerny-Turner type Focal length: 1000 mm Grating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm Reciprocal linear dispersion: 0.26nm/mm Resolution:≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating) Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nm Minimum pace of stepping motor: ≤0.0006 nm Exit Slit:12μm;Entrance Slit:10μm
Photoelectric Converter Performance Photomultiplier tube specification: R293/R928 Negative HV on PMT: 0-1000V;Stability: <0.05%
Overall Performance Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating) Repeatability: RSD(Relative Standard Deviation)≤1.5% Stability: RSD(Relative Standard Deviation) ≤2% Detection Limits (µg/L):
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: inductively coupled plasma optical emission spectrophotometer geology inductively coupled plasma optical emission spectrophotometer |
![]() |
High Performance Atomic Absorption Spectrophotometer Flame / Graphite Furnace Atomization System |
![]() |
AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching |
![]() |
AA1800S Automatic Collimation Aas Atomic Absorption Spectroscopy Instrument |
![]() |
8 Lamp Flame Spectrophotometer Graphite Furnace Integrated Machine Aa-1800el |
![]() |
Macy Lab Absorption Spectrophotometer With Flame And Graphite Furnace System |
![]() |
Geology Inductively Coupled Plasma Optical Emission Spectrophotometer Icp-6800 |