China Non Destructive Testing Equipment manufacturer
HUATEC GROUP CORPORATION
HUATEC GROUP CORPORATION Professional Non Destructive Testing Equipment
10
Home > Products > Ultrasonic Calibration Blocks >

Chrome Plating Penetrant Ut Test Block Test Specimen YM-B3

Chrome Plating Penetrant Ut Test Block Test Specimen YM-B3

Brand Name HUATEC
Model Number YM-B3
Certification ISO,CE,Gost
Place of Origin China
Minimum Order Quantity 1 set
Payment Terms L/C, T/T, Western Union,Paypal
Supply Ability 100 sets per month
Delivery Time 3-7 days
Packaging Details in High quality carton
Product name Penetrate testing test specimen
Model YM-B3
Testing standard JB/T6064-2006、NB/T47013.5-2015
Flaw width target value 0.5µm
Detailed Product Description

Chrome Plating Test Block Penetrant Testing Block Test Specimen YM-B3

 

A test block with the size of 130mm×40mm×4mm and the material of 0Cr18Ni9Ti or other stainless steel materials was chromium plated on one side, and three radial crack areas were formed by applying different loads on the back of the block by Brinell hardness method. The location numbers were 1, 2 and 3 in order of size. The position, spacing and other requirements shall be in accordance with the relevant provisions of Type B test blocks in JB/T 6064 -- 1992. The crack sizes correspond to crack location numbers 2, 3 and 4 on JB/T 6064 -- 1992 type B test blocks.

 

The chrome plating test block is mainly used to check the sensitivity of the penetrant detection agent system and the correctness of the operation process.

If it is found that the test block is blocked or the sensitivity is reduced, it must be repaired or replaced in time.

The test block should be thoroughly cleaned with acetone after use. After cleaning, the sample is stored in an airtight container containing a mixture of acetone and anhydrous alcohol (mixing ratio by volume: 1∶1) or by other effective methods.

 

Specification

All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated.
Material:Test Report according to ISO 10474-3.1.B,JIS G 0415-3.1.B
Depth100µm
Width (target value)0.5µm
 Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled.
TraceabilityCalibration standards used are traceable to international standards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled

Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B

Material: Stainless steel chrome plating

Flaw depth:100µm

Flaw width target value:0.5µm

Testing standard: JB/T6064-2006,NB/T47013.5-2015

Product Tags: chrome plating ut test block   penetrant ut test block   chrome plating ut calibration blocks  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: HUATEC GROUP CORPORATION
Subject:
Message:
Characters Remaining: (80/3000)