Self-Contained CO2 Fire Suppression System For Industrial Electrical Panel Safety
|
Product Introduction:The FM200 Cabinet Fire Suppression System is a pre-engineered, all-in-one fire detection and extinguishing unit specially designed for enclosed cabinets and rack environments. This integrated system combines fire detection, clean agent storage, discharge nozzle, pressure indicator, and signal feedback into one compact module. It is ideal for server racks, electrical control panels, telecom cabinets, UPS cabinets, and other confined equipment spaces. Using HFC-227ea (FM200) clean agent, the system rapidly
suppresses Class B, C, and electrical fires without leaving residue
or damaging sensitive electronic equipment. Why Choose FM200 Integrated Cabinet Fire System? ✔ Fast automatic fire detection and suppression Designed specifically for limited-space environments, this system eliminates the complexity of traditional centralized fire suppression systems. Parameter:
Working Principle:1️⃣ Thermal Glass Bulb Activation (68°C standard)When cabinet temperature reaches the preset level (68°C or customized), the glass bulb bursts automatically, releasing FM200 agent instantly. 2️⃣ Detection Tube Activation (160°C ±10°C)The fire detection tube ruptures at the hottest point when exposed to flame, triggering the discharge of the clean agent directly at the fire source. Both methods ensure rapid response without the need for smoke detectors, control panels, or electrical triggering systems. Main Technical Parameters and Features:
Device Application Locations:1. Inside server cabinets for IT and computer systems; 2. Inside server cabinets for telecommunications and communication systems; 3. Inside control cabinets for banking equipment; 4. Various control cabinets for machinery and other industries Competitive Advantage:
Installation and Maintenance:1. Cabinet Heptafluoropropane Gas Fire Extinguishing Device Installation The installation of the cabinet heptafluoropropane gas fire extinguishing device is as shown in the figure above. Install the cabinet heptafluoropropane gas fire extinguishing device in a drawer-style arrangement into the cabinet and secure it securely. The thermal release assembly and fire detector tubes of the cabinet heptafluoropropane gas fire extinguishing device are also arranged as shown above. The thermal release assembly is secured to the cabinet using the corresponding accessories. The fire detector tubes should be arranged in an S-shaped pattern, preferably in areas prone to fire, and secured with cable ties. 2. Personnel performing installation, commissioning, and operation should be familiar with the basic structure, operating principle, performance, and operating procedures of the device, as well as the structure and operating conditions of each valve component. 3. The device should be installed away from direct sunlight and heat sources. Ensure that the device is not subject to vibration and impact. The device should be secured within a protected area using brackets. 4. After clearly understanding the above two points, proceed with the specific installation work: 4.1 Installing the Heptafluoropropane Gas Fire Extinguishing System in the Cabinet: 4.1.1 Selecting a Location for the Heptafluoropropane Gas Fire Extinguishing System in the Cabinet: Select a suitable U-shaped space in the upper area of the cabinet. The location should be convenient for daily inspection and installation, avoiding areas with heavy wiring. 4.1.2 Use the cabinet's built-in rails or tray to secure the system. Secure the system with screws through the two screw holes on the front panel. Once secured, the system is installed. 4.2 Components and Installation: 4.2.1 The system interfaces include: copper pipe interface, switch, pressure gauge, signal feedback device, fire detector tube, temperature-sensing glass bulb, and fire extinguisher release nozzle. The fire extinguisher release nozzle is located on the front panel, and the other interfaces are located on the back panel. 4.2.2 Installation of the Temperature-Sensing Glass Bulb and Fire Detector Tube: 4.2.2.1 Installation of the Temperature-Sensing Glass Bulb: The temperature-sensing glass bulb is already fixed to the device and does not require installation. 4.2.2.2 Installation of the Fire Detector Start Pipe: Remove the plug from the air throttle, insert the fire detector tube into the pin-shaped connector, and tighten the copper cap until secure. Observe the cabinet space and select an appropriate piping layout. The piping layout principles should first ensure maximum cabinet coverage, then route the fire detector tube through the most fire-prone areas, and finally, aesthetics. The fire detector tube ends in a standard plug. First, insert the internally threaded plug into the fire detector tube. Then, firmly insert the other plug into the fire detector tube. Connect the two pieces and tighten. 4.3 Signal Feedback Device Interface: Connect the signal feedback device to the system according to the marking requirements. 5. Maintenance and Management of Cabinet Heptafluoropropane Gas Fire Extinguishing Devices A dedicated maintenance manager should be assigned to manage the maintenance of cabinet heptafluoropropane gas fire extinguishing devices. Maintenance records should be kept. The manager should be familiar with the device's operating principles and performance. a. Inspections should be conducted twice weekly and meet the following requirements: a1. The pressure reading on the cabinet heptafluoropropane gas fire extinguishing device should be within the green zone; a2. The switch on the container valve should be in the "on" position; a3. The device should show no abnormalities. b. The device components should also be inspected quarterly and meet the following requirements: b1. Device components should be free of mechanical damage, surface rust, coating protection should be intact, and nameplate markings should be legible; b2. The fire extinguishing agent container, fire detection hose, release hose, nozzle, etc. should be secure and reliably connected. c. Conduct a comprehensive annual inspection and maintenance of the cabinet gas fire extinguishing system. In addition to meeting the requirements in a and b, the following requirements must also be met: c1. Check the fire extinguishing capacity of the device's container by weight. The requirement is: Fire extinguishing capacity ≥ (container volume x 1.15 g/L) x 90%. If the requirement is not met, refill the fire extinguishing agent. c2. Observe the pressure gauge to check for leaks in the cabinet's HFC-227ea gas fire extinguishing system. If the pressure gauge is outside the green zone, check the fire extinguishing capacity by weight. If the fire extinguishing capacity leaks ≥ 10%, consider replenishing the fire extinguishing agent and restoring the pressure. c3. The fire detection tube must be free of deformation, corrosion, damage, or aging. c4. Maintenance and management of the fire extinguishing agent container must be carried out in accordance with the "Safety Supervision Regulations for Gas Cylinders." 6. Unauthorized personnel are prohibited from touching or tampering with the components of this fire extinguishing system to avoid accidents.
Company Introduction: FAQ:F:Are you a trading company or a manufacturing factory? Q:We are both a manufacturer and a trading company. We have our own
factory for nearly 15 years, and we provide better services to
overseas customers. F:Can you do OEM production for me? A:We accept all OEM orders, just contact us and provide your design
plan, we will provide you with a reasonable price as soon as
possible. F:How do you ensure product quality? A:We have TUV/SGS/ISO quality control system and strictly implement
it. We have a professional quality inspection team, and each
packing worker will conduct a final inspection before packaging
according to the quality inspection instructions. F:Apart from the all-in-one machine, do you have any other conventional fire-fighting equipment? A:Of course, we have a complete set of professional fire
extinguishing equipment, ranging from sound and light alarms to
windbreak and smoke exhaust valves, as well as fire extinguishing
systems such as FM200, CO2, and Novec1230. We welcome your
inquiries! F:How about the delivery time? A:According to the minimum order quantity, delivery will be made in 10-15 working days after receiving the deposit. Normally, an order of a 20-foot container takes 30-35 days to complete. Welcome to inquire about the specific delivery time according to your order quantity! |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: UL FM CE Certified FM200 Fire Suppression System Compact Drawer-Type Installation Cabinet Fire Suppression Unit 1.6MPa Storage Pressure Rack Fire Suppression System |
|
Professional Grade Steel Cylinder / FM200 Compatible Fire Suppression Vessel |
|
HFC-227ea / FM200 Cabinet Automatic Fire Suppression Unit |
|
Self Contained Inert Gas Fire Suppression System For Electrical Control Panels |
|
Compact FM200 Fire System With Automatic Detection For Server Cabinet Protection |
|
Self-Contained CO2 Fire Suppression System For Industrial Electrical Panel Safety |
|
Automatic Rack Mount Fire Suppression Extinguisher Easy To Install 1.15kg/L Max Filling Rate |