High Precision TG4100B Digital Ultrasonic Thickness Gauge 128X64 Pixel LCD With Backlight
|
TG4100B Ultrasonic Thickness Gauge
Usage TECHNICAL DATA
Display 128X64 Pixel LCD with backlight Measuring range 0.8 mm-- 300.0 mm in steel depending on the probe Special request can reach measuring range up to 500mm Tolerance +/-0.05 mm in steel Display resolution 0.1 mm (TG4000B)/0.01mm (TG4100B) Built-in standard block 4.00 mm Memory 500 datas in 5 groups, memory does not lose after powering off Velocity range 1000-9999 m/s Power 2 pcs 1.2 V AAA batteries Outside dimension 149X73X32 mm Net Weight 160 g FEATURES
Probe Zero Adjustment: Selectable: 1-point calibration: normal measurement 2-point calibration: curve surface measurement or other special application with a high precision V-Path Correction: Automatic Automatic self-calibration Couplant indicator Automatic power off in 5 minutes and manual power off function High-low limit alarm LCD brightness adjustable Measurement Update rate: 4 Hz Minimum value scanning (MIN Capture mode): catch the minimum value during the measurement. Can modify systematical errors by using the 4mm standard block on the instrument. Low battery indicator Metric/imperial optional Dataview for PC communication
STANDARD DELIVERY
TG4100B main unit Hard carrying case Couplant bottle Standard 8 mm, 5 MHz probe PT-08 with cable
OPTIONAL ACCESSORIES
4 steps steel test block 7 steps metrics steel test block 5 MHz, 4 mm contact probe 10 MHz, 4 mm, contact probe 5 MHz high temp. probe Probe cables Water proof housing Dataview CD and communication cable optional
PROBE OPTIONAL Probe model Frequency Contact area Testing Range (steel) Contact Temp. Cast iron probe ZT-12 2MHz 16.2mm 4.0-300.0mm --10--60℃ Standard probe PT-12 5MHz 12mm 1.0-200.0mm --10--60℃ Standard probe PT-08 5MHz 10mm 0.8-100.0mm --10--60℃ Small probe PT-06 7.5MHz 7.6mm 0.8-30.0mm --10--60℃ Small probe PT-04 10MHz 5mm 0.8-20.0mm --10--60℃ High temp. probe 5MHz 14mm 4.0-80.0mm up to 300℃
Standard Configuration
Optional Configurations
Pipe Walls Measurement The thickness of a pipe can be measured accurately with this gauge. The measurement range is shown in the following table:
PT-06 ≥φ30 ≥ 0.8 PT-04 ≥φ20 ≥ 0.8 The split-plane of the probe may be along the pipe axis or perpendicular to it as shown in the following figures: Pipe samples In this case, the readings on the screen will change with some regular patterns and the smallest display value should be taken as the thickness value. For small pipes, measurement should be made in both directions (moving probe a little bit). For large pipes, measure the thickness of the wall along the direction perpendicular to the pipe axis. See the following figure: Bottom view of probe Sound Velocities of Some Common Materials
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: digital ultrasonic thickness gauge through coating thickness gauge |
![]() |
RS485 Ethernet Non contact no coupling Single echo Dual echo EMAT Ultrasonic Thickness Gauge TG-14D |
![]() |
A Scan B Scan EMAT Air Coupling Ultrasonic Thickness Gauge With High Temperature Surface |
![]() |
A scan EMAT Air Coupling Ultrasonic Thickness Gauge with high temperature surface |
![]() |
High Precision Steel Thickness Measuring Device CE Certified RoHS Certification |
![]() |
High Frequency 5MHz Ultrasonic Thickness Gauge Powered By 4*1.5V AA Battery For Precise Measurement |
![]() |