China Online High Frequency UPS manufacturer
Shenzhen HRD SCI&TECH CO.,Ltd
HRD UPS---Global High-end Power Solutions Expert! Your best trustable OEM/ODM power partner! ISO9001-2015,ISO14001 , ISO18001, TLC, CQC, TUV ,CE certified.
17
Home > Products > Rack Mount Ups >

1KVA - 10KVA Rack Mount UPS / 19 Inch LCD Double-Conversion UPS

1KVA - 10KVA Rack Mount UPS / 19 Inch LCD Double-Conversion UPS

Place of Origin Shenzhen China
Brand Name HRD/OEM/ODM
Certification CE, ISO9001:2008
Model Number PMR01 PMR02 PMR03 ;PCR06,PC10
Minimum Order Quantity 50PCS
Price 120-800USD/PCS;
Packaging Details 1PCS/CTN, standard for export
Delivery Time 3 weeks after down payment
Payment Terms TT
Supply Ability 10000pcs/ month
Warranty 18months after shipment with 10years technical support
Product Name rack mounted ups
Model PMR01S,PMR01L,PMR02S
Capacity 1KVA/0.8kW,1KVA/0.8kW,2KVA/1.6kW
Phase Single
Input PF above 0.98
THDi less than 5%
Detailed Product Description

1KVA - 10KVA Rack Mount UPS / 19 Inch LCD Double-Conversion UPS

 

System introduction:
PCM Rack Series is a full DSP controlled, adopted 3 level technology Online HF UPS.
Its Online double conversion,1/1 Phase pure sine wave
with smart design and high reliable, overall efficiency>95% .
Its a high reliability and energy saving green UPS.

Technical Specification:
◆ Most advanced power supply rectifier and PFC Technology. Input Power Factor 0.99, THDi≤3.5%,
◆ Wide Input Range 110-300Vac,which reduces the battery usage time and maximize battery lifespan.
◆ Adopt Latest 3 Lever technology to meet the critical loads, with output PF =1.0 ,overall efficiency up to 95% (98.5% under ECO mode),
◆ Powerful load capability with output short circuit protection technology
◆ Compatible with all kinds of generators to save customers costs.
◆ IBM charger with current 1-12A adjustable,constant charging, float charging and equalized charging , to maximize the battery life and fast charging requirement.
◆ Powerful battery anti-reverse connected alarm and protection.In case the DC is not connected,
Or reversely connected, UPS cannot turn on and show DC failure.
◆ Battery configuration: optional with 16/18/20pcs for 6-10kVA without changing any spares;
◆ Powerful battery maintenance function, battery test on the LCD screen directly,battery end voltage settabe on LCD.
◆ Smart identify of short circuit, if the short circuit lasts within 3s, UPS will restart on inverter automatically, if the short circuit lasts over 3s,UPS will lock the inverter with long time alarm.
◆ Under emergency status, UPS output can be remote controlled under EPO mode
◆ Battery Self-testing on the LCD directly. Battery Capacity, UPS working mode (Online or ECO first) can be set on the screen.

◆ Rotatable LCD display ,convenient for vertical installation.
◆ Intelligent mute control technology and scientific ventilation design greatly reduce the UPS running noise.
◆ Standard 19inch 2U Rack-mount design
◆ Highly integrated PCBA board and wires design makes the system convenient in maintenance and greatly saves after-sale time
◆ SNMP card (optional)

 

PM series rack mount online UPS 1-3kva  
Perfect Application:     
Computer center, network center, communication system  
 automatic control system data center or other critical systems.  
   
 
   
Main Features:     
19inch,2U and 3U Rack mount     
High frewuency and online double conversion   
Wide input voltage (110-285Vac or 65-148Vac)   
Self-diagnosis system at ups start    
Digital control technoloy and advanced PFC   
Output PF0.8,(0.9 optional)    
Lighting and surge protection 1050j    
Generator compatible     
Smart RS232(USB,SNMP OPTIONAL)    
EMI/RFI noise filter     
Overview
With true double-conversion design, PowerMaster series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. It's perfect protection for your precisous servers and workstaiosn. 
Specifications      
ModelPMR01SPMR01LPMR02SPMR02L PMR03SPMR03L 
Capacity1KVA/0.8kW1KVA/0.8kW2KVA/1.6kW2KVA/1.6kW3KVA/2.4kW3KVA/2.4kW
PhaseSingle
Input voltage 
Input PFabove 0.98
THDiless than 5%
Rated voltage220v/230v/240Vac or 110/120/127Vac
Input voltage rangeLow line  transfer:176 VAC ± 3% @ 100% load
130 VAC ± 3% @ 50% load
85-148Vac( for 110/120/127Vac)
Low line comback:188VAC ± 3% @ 100% load
142 VAC ± 3% @ 50% load;
100vac±5Vac(110/120/127Vac)
High Line Transfer:286 ± 3%148Vac ± 3%(for 110/120/120vac);
High Line Come Back:271 ± 3%;
145Vac±5Vac(110/120/127Vac)
Rated frequency50/60hz(auto sensing)
Input frequency range46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz
By-pass input
Input voltage range170VAC—270VAC±5V
Frequency following range46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz
Recharge battery
Floating charge voltage28/41VDC55/84/110VDC84/110VDC
Recharging current1A(inbuilt battery)8A1A(Rack batt.case)8A1A(Rack batt.case)8A
Battery
Battery quantity24/36VDC48V/72/96VDC72/96VDC
AC output
Power factor0.8
Phasesingle
Rated voltage220v/230v/240v+/-1.5%
Frequency50/60hz
Frequency stability±0.1HZ(battery inverter)
Voltage stabilitywithin±1.5%( Static)
  Crest factor3:1(max)
Wave distortionLinear load less 3%,Non-linear load less 5%;
Over load ability30s when overload is 108%~150%;200ms above 150%;
Transfer time0ms
Alarm
AC abnomalAlarm every 4 seconds
Battery low voltageKeep alarm every 1 second
OverloadKeep alarm every 0.5 second
FailureKeep alarm
System
Efficiencyabove 87%
DisplayLCD+LED
Protection

Output short circuit , Overload , Output low voltage, Battery low voltage,               

  Over-temperature etc.

 over-voltage protection,over-tempreture protection for charger PCB,and soft-start function for each function module.
InfterfaceRS232(USB OPTIONAL)
Working Temp.0~40℃
Relative humidity0~90%( No coagulation)
CoolingIntelligent speed-control Fan
Input & output Socket(Optional)
Others
Surge protectionIEC60664—1 Graded protection
EMIEN 55022  Grade A
ESDIEC 1000-4-2:Grade 3
EFTIEC 1000-4-4:Grade 3
RSIEC 1000-4-3:Grade 3
SURGEIEC 1000-4-5:Grade 3
Physical
Weight(N/G)kgs12.5/14.57.0/8.011.0/13.028.0/31.011.0/13.028.0/31.0
Unit Size
(D*W*H)
440* 440 *87 mm440* 440 *87 mm(long run model)
440* 440 *134 mm( inbuilt battery model)
Packing Size
(D*W*H)
570*570*185mm570*570*185mm(long run model),2U
640*570 *230mm( inbuilt battery model),3U
PC Plus Rack mount 6-10kva with output PF0.9
•19'inch, rack mount, 3/4U design 6kva to 10kva   
•True online high frequency double-conversion 
•Advanced DSP controlled ,excellent performance with super high quality 
•Output Power Factor 0.9 
•Wide input frequency range (40-70Hz)
•Wide input voltage range
•50Hz/60Hz frequency converter mode
•Eco mode operation for energy saving (Optional) 
192Vdc and 240Vdc convertible easily
•Emergency power off function (EPO) 
History event record function,100 events
•Cold start and AC start function
•Automatic 4 levels speed fan control according to load and temperature
•Advanced N+1 redundancy parallel technology(Max.6units)
•Support any kinds of  Generator 
      
PC Plus RACK MOUNT 6K/10K  ONLINE HF UPS 
      
MODELPCPR 06SPCPR 06LPCPR 10SPCPR 10L
PHASE1 phase in / 1 phase out
CAPACITY6Kva / 5.4Kw10Kva/ 9Kw
INPUT
Voltage RangeLow Line Transfer 176 VAC ± 3% @ 100% load
130 VAC ± 3% @ 50% load 
Low Line Comeback 188 VAC ± 3% @ 100% load
142 VAC ± 3% @ 50% load 
High Line Transfer 286 VAC ± 3%  
High Line Comeback 270 VAC ± 3%  
Frequency Range 40-70Hz
following range 46~54 Hz @ 50Hz ,56~64 Hz @60Hz
PhaseSingle phase with ground
Power Factor> 0.99  @ 100%load
OUTPUT
Output Voltage208/220/230/240 VAC
AC Voltage Regulation ± 1%
Frequency Range (Synchronized Range)46~54 Hz @ 50 Hz / 56~64 Hz @ 60 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1 (max.)
Harmonic Distortion≤ 3 % THD (Linear Load) , ≤  6 % THD (Non-linear Load)
Transfer TimeAC Mode to Batt. ModeZero
Inverter to BypassZero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
AC Mode92%
Battery Mode91%
BATTERY
Standard modelBattery Typelead-acid battery maintanence free
Numbers16/20Pcs
Typical Recharge Time3 hours recover to 90% capacity4 hours recover to 90% capacity
Charging Current (max.)1A ±10%4A±10%1A ±10%4A ±10%
Charging Voltage 220/273 VDC ± 1%
Long-run ModelBattery cabinet 16/20pcs 7ahwithout batt. 16/20pcs9ahwithout batt.
INDICATORS
LCD PanelUPS status, Load level, Battery level, Input/Output voltage,
output current,Bus voltage, Temp, and warning
 and fault code and events 
ALARM
Battery ModeSounding every 4 seconds( can mute)
Low BatterySounding every second
OverloadSounding every second
FaultContinuously sounding
PHYSICAL
Standard ModelDimension,
 D X W X H (mm)
UPS Unit : 580 X 438 X 176 [4U]
Battery Pack : 580 X 438 X 176 [4U]
UPS unit: 580 X 438 X 176[4U]UPS Unit: 668 X 438 X 176 [4U]
Battery Pack : 580 X 438 X 176 [4U]
UPS unit: 668 X 438 X 175[4U]
Net Weight (kgs)UPS Unit : 22 kgs
Battery Pack : 62kgs
22kgsUPS Unit : 25 kgs
Battery Pack :75 kgs
25kgs
ENVIRONMENT
Operation Humidity20-90 % RH @ 0- 40°C (non-condensing)
Noise LevelLess than 55dBA @ 1 MeterLess than 58dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser

 

Product Tags: rack ups systems   rack mounted ups   19 inch lcd rack mounted ups  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shenzhen HRD SCI&TECH CO.,Ltd
Subject:
Message:
Characters Remaining: (80/3000)