| Item | Specifications |
|---|
| Programming method / Control method | Relay symbol / Cyclic operation |
| Number of I/O points : No expansion (Control unit only) | 32 points [Input : 16, Transistor output : 16] |
Number of I/O points : With expansion 1 Same type of control and expansion units | Max. 128 points (Note: For the limitations while operating units,
reter to the manual.) |
Number of I/O points : With expansion 2 Mix type of relay and transistor units | Max. 128 points (Note: For the limitations while operating units,
reter to the manual.) |
| Program memory | EEPROM (no backup battery required) |
| Program capacity | 32 k steps |
| Number of instructions : Basic | 110 approx. |
| Number of instructions : High-level | 210 approx. |
| Operation speed : Up to 3,000 steps | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. |
| Operation speed : 3,001st and later steps | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. |
| Operation memory : Relay : Internal relay (R) | 4,096 points |
| Operation memory : Relay : Timer / Counter (T / C) | 1,024 points |
| Operation memory : Memory area : Data register (DT) | 32,765 words |
| Operation memory : Memory area : Index register (IX, IY) | 14 words (IO to ID) |
| Master control relay points (MCR) | 256 words |
| Number of labels (JMP and LOOP) | 256 labels |
| Differential points | Equivalent to the program capacity |
| Number of step ladder | 1,000 stages |
| Number of subroutines | 500 subroutines |
| Special functions : High speed counter | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15
kHz max. each) (Note: For the limitations while operating units,
reter to the manual.) |
| Special functions : Pulse output | 4 points (50 kHz max. each) 2 channels can be controlled
individually. (Note: For the limitations while operating units,
reter to the manual.) |
| Special functions : PWM output | 4 points (6 Hz to 4.8 kHz) |
| Special functions : Pulse catch input / interrupt input | Total 8 points (with high speed counter) |
| Special functions : Interrupt program | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> |
| Special functions : Periodical interrupt | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms
to 30 sec. |
| Special functions : Constant scan | In units of 0.5 ms : 0.5 ms to 600 ms |
| Special functions : RS-232C port | One RS-232C port is mounted (3P terminal block) Transmission speed (Baud rate) : 2,400 to
115,200 bits/s, Transmission distance : 15 m 9.843 ft. Communication method : half duplex |
| Maintenance : Memory backup : Program and system register | Stored program and system register in EEPROM |
| Maintenance : Memory backup : Operation memory | Backup of the entire area by FeRAM (without the need for a battery) |
| Maintenance : Self-diagnostic function | Watchdog timer (690 ms approx.), Program syntax check |
| Maintenance : Real-time clock function | Not available |
| Maintenance : Other functions | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection |