DC48V 3U BTS Telecom Rectifier Systems with RS485 Remote Monitoring
|
DC48V 3U BTS Telecom Rectifier Systems with RS485 Remote Monitoring
Product Overview of 3U BTS Telecom Rectifier System
The ET48300-M5E63 is a DC rack power system developed by ESTEL, provides a high-capacity, resilient DC power solution designed specifically for telecommunications infrastructure, data center operations, and industrial applications requiring dependable DC power distribution. It accepts 380VAC (compatible for single-phase and three-phase) and delivers a stable DC output adjustable between –43VDC to –58VDC, with a nominal operating point of –53.5VDC. Offering a maximum output capacity of 18kW, this system reliably supports high-demand installations while achieving power conversion efficiency exceeding 96%. The DC distribution panel is equipped with 1*250A battery circuit breakers and includes LLVD & BLVD functionality for secure and flexible power management. System intelligence is provided by a dedicated controller featuring 3 analog sensor inputs, 7 digital status inputs, and 6 configurable dry-contact alarm relays. Remote monitoring and management are enabled via RS232/485 and SNMP interfaces, while an integrated LCD display allows for local status viewing and configuration.
AC Specification of 3U BTS Telecom Rectifier System Input mode: 380VAC, compatible with both single-phase and three-phase configurations Input frequency: 45Hz to 65Hz (rated 50Hz/60Hz)
DC Specification of 3U BTS Telecom Rectifier System Output voltage: -43V to -58VDC (rated -53.5VDC) Maximum capacity: 18kW (6 x 3kW rectifier modules, N+1 redundancy) Battery breaker: 1 x 250A
Load breakers of 3U BTS Telecom Rectifier System LLVD: 1 x <125A/1PN (reserved) BLVD: 6 x ≤63A/1PN + 2 x ≤125A/1PN (reserved)
Rectifier Module of 3U BTS Telecom Rectifier System Input voltage: 85VAC ~ 300VAC (rated 220VAC) Efficiency: >96% Rated power: 3000W (176~300VAC) Cooling mode: Forced cooling Power factor: ≥0.99 THD: ≤5% DC output: -43 ~ -58VDC (rated -53.5VDC), maximum 55A
Specifications of 3U BTS Telecom Rectifier System
Structure of 3U BTS Telecom Rectifier System
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: DC48V telecom rectifier system 300A telecom power system RS485 remote monitoring rectifier | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Customized Design and Produce Hybrid Telecom Power Supply Telecom Rectifier with Solar Module MPPT Remote Monitoring with SNMP |
|
48V 40A Telecom Power System and Scalable Solution for Networking and Industrial Applications |
|
Low Cost Customizable Integrated Solution Hybrid Energy Telecom Power System With Solar Power Grid Diesel Generator Battery For Outdoor Telecom Site Power Supply |
|
28U Intergrated Outdoor Power Cabinet With Rectifier System UPS Battery Energy Storage Enclosure |
|
Integrated Outdoor Telecom Cabinet Two Compartment UPS Cabinet |
|
ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution |