1. GPE48150G System Configuration
The system consists of distribution unit, rectifier module (1 min.,5 set max.) and monitoring module. The configuration is optional, as following table:
2. Operating Principle
AC mains is first input AC-INPUT MCB and then fed into the rectifier module after the SPD and EMI filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The LOAD1-,LOAD2-,LOAD3-,LOAD4-,LOAD5- link in series to 2 power-off contactors KM1,KM2.The user’s battery is connected to the DC output side through MCB BAT and KM2, and the MCB provides disconnection control, over-load and short-circuit protection to the battery. Under normal conditions, every parameter of rectifier modules and
distribution unit are controlled by the monitoring module,
operating according to the pre-set parameter or user’s commands. If
AC mains fault, the battery will power to the system. With the
battery discharge, the terminal voltage of the battery starts to
descend. When the voltage is under -47V±0.5V, the monitor reports
DC under voltage alarm signal and when the voltage is under
-46.0V±0.5V (adjustable), the KM1cuts off LOAD3-,LOAD4-,LOAD5- and
retaining power to LOAD1-,LOAD2-. If the voltage drops to
-43.0V±0.5V (adjustable), the KM2 will cut off output of
LOAD1-,LOAD2- and then the power system will stop working. If the
external AC mains recovers, the system will normally work again.
(All above monitoring data are system default values and can be
reset by user). 3. GPE48150G Properties
4. Electric Connection
Chassis connects with external electric through system interface board. As shown in figure below:
Cable connetors descriptions: (1) N is the natural wire, L is the live wire,PE is the ground wire (2) B1- and B2- is the BATT (-),B1+ and B2+ is the BATT (+) (3) 1-,2-,3-,4-,5- are LODA1, LODA2…LODA5 load (-) (4) 1+,2+,3+,4+,5+ are LOAD1, LOAD2…LOAD5 load (+)
5. Application
(1) Small scale program controlled exchanges (2) Access network (3) Transmission equipment (4) Mobile communication (5) Satellite communication ground station (6) Microwave communication
6. Features
(1) Adoption of active power factor compensation technology with factor >0.98 (2) Wide operating range of AC input voltage: 90~280Va (3) Operating temperature range: -25°C~+55°C (4) Zero current/voltage switching tech with high efficiency ≥92% (5) Perfect battery management prolongs battery lifetime: charge/discharge management, battery temperature compensation, battery capacity test, low-voltage protection (6) Hot-swappable (7) Input under/over voltage protection (8) Output over voltage protection (9) Output over current protection (10) Output short circuit protection (11) Auto current sharing, parallel operation (12) Embedded mounted (13) Perfect surge protection function 20KA (8/20 US)
7. Packing and Shipping
Email: info@estel.com.cn lxf.estel@hotmail.com |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: telecom rectifier module dc rectifier system | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
ET48300 Telecom Grade Solar Programmable Hybrid Rectifier Power with AI DI DO |
|
8U Ultra High Capacity DC Power System for Industrial Communication Hubs |
|
Telecom Rectifier System 24V 25A DC Power Conversion Solution for Telecom Network Operations and Stable Power Supply |
|
Compact Telecom DC Rectifier Power Supply for Medium Power Network and Backup Applications |
|
1U Rack Mount Integrated DC Power System with Dual Rectifier Slots Monitoring Unit RS485 or LAN Interface |
|
Customizable Indoor Power Distribution Cabinet For Data Centers And Power Supply Stations Grid |