ABB Module RF616 3BSE010997R1 ABB RF616 3BSE010997 R1 ASTRA, NOVA Free shipping
|
ABB Module RF616 3BSE010997R1 ABB RF616 3BSE010997 R1 ASTRA, NOVA Free shipping
Product Description:
nput voltages that exceed the measuring range cause the overflow numerical value of +32767. If the measured value is below the range, the underflow numerical value Input currents that exceed the measuring range cause the overflow numerical value of +32767. If the measuredvalue is below the range, the underflow numerical value of -32767 is set. The input impedance is ca. 330 Ω. The current input has a self-protecting mechanism. If the input current gets too high, the shunt is switched off and the value for range overflow is generated. About every second, the unit tries to switch on the shunt again. In this way the correct measurement will succeed after the current has reached a normal value again.1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows
Related Product Recommendation:
Product's Character:
In case of a configured plausibility monitoring, range underflow
and range overflow by 2...3 % result in an The trigger of the
self-protecting mechanism is displayed by the red LED Ovl as long
as the overload is present. In the PLC system an error message is
then stored (FK4, error number 4). The open-circuit monitoring
begins below ca. 3 mA. The value of the range underflow is stored.
If the ope circuit monitoring is configured, the open-circuit event
is displayed by the red LED Ovl as long as it is present. In the
PLC system an error message is stored (FK4, error number 9). The
following figure shows the connection of 2-pole passive- type
analog sensors 4...20 mA. If the analog current sensors 4...20 mA
are powered from a separate power supply unit, the reference
potentials 0V (of the separate power supply unit and the power
supply unit for the 07 KT 94) must be interconnected
CI547 3BNP004429R1 MB300 Communication Board with Slave Processor
ABB CI670 3BHT300017R1 Master Fieldbus Module ABB
The use of the product: 1.automobile manufacturing, 2.tobacco, 3.plastic machinery, Product's advantages: 1.Customer service in 1-4 hours. If there's any question, please contact with our sales.
Our advantages: 1.Provides the lowest Total Cost of Ownership (TCO)
Frequently Asked Questions: 1.Q:How about the payment terms ?
2.Q:What about your shipping terms ?
3.Q:What about your lead time ? Send your Inquiry details in the Below, Click "Send" Now! Contact Information: Contact:Miya ( manager) Email :sales@mooreplc.com |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: abb plc advant controller 31 |