C.4 Male Luer Reference Connector
|
Detailed Product Description
|
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector and C.4
Male Luer Reference Connector ISO 80369-7 C.4 Male Luer Reference Connector Compatibility/Interchangeability: Between ISO 594/2 Fig 7 and ISO 80369-7 Fig C.4 The ISO 594/2 Figure 7 Male Luer Reference Conical Fitting is
replaced by ISO 80369-7 Fig C.4 Male Luer Reference Connector. The
ISO 80369-7 Figure C.4 is identical to the ISO 594/2 Figure 7
Reference Fitting. ISO 80369-7 Fig C.4 and ISO 594/2 Fig 7 are
completely interchangeable. Design Details: Keeping with the requirements of ISO 80369-7, the Reference
Connectors we produce are from hardened stainless steel. The design
details might vary by manufacturer so please communicate with us to
make sure you understand the configuration before you place the
order. The ISO 80369 Reference Connectors are an integral part of
Luer needle and syringe testing. It can perform tests: The ISO 80369-7 Figure C.4 Male Luer Reference Connectors are used
for testing Female Luer Connectors for: Leakage; Separation from
unscrewing; Stress cracking; and Non-interconnectable
characteristics in the ISO 80369-7; Clause 6 specified tests. Below is the list of tests which are accomplished by using the ISO
80369-7 Fig C.4 Male Luer Reference Connector: ISO 80369-7 Clause... 4.1: Non-Interconnectivity 6.1: Fluid Leakage 6.2: Sub-Atmospheric Pressure Air Leakage 6.3: Stress Cracking 6.5: Resistance To Separation From Unscrewing ISO 80369-7 Fig C.2 Male Reference Luer Slip Connector Compatibility/Interchangeability Between ISO 594/1 Figure 5 and ISO
80369-7 Figure C.2: ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is 100%
backward compatible with the ISO 594/1 Figure 5 Reference Fitting;
so it can be certified and used in ISO 594/1 designated testing. If you request a quote for a new ISO 594/1 Fig 5 Reference
Connector from us; we will quote an item which will pass both ISO
594 and ISO 80369-7 requirements. It can perform tests: The ISO 80369-7 Fig C.2 Male Reference Luer Slip Connector is used
for testing Female Luer Connectors for: Leakage; Separation from
axial load; Stress cracking; and Non-interconnectable
characteristics in the ISO 80369-7; Clause 6 specified tests. Design Details: Keeping with the requirements of ISO 80369-7,the Reference
Connectors we produce are from hardened stainless steel.The design
details might vary by manufacturer so please communicate with us to
make sure you understand the configuration before you place the
order. The ISO 80369-7 Fig C2 Male Reference Luer Slip Connector is
an integral part of Luer needle and syringe testing. |
| Product Tags: ISO 80369-7 C.4 Male Luer Reference Connector C.4 Male Luer Reference Connector C.2 Male Reference Luer Slip Connector |
Related Products
|
KP-1230S Dielectric Strength Tester for Quadripolar Connector Testing with Monophasic Truncated Exponential Waveform Compliant with ISO 27186:2020 |
|
ISO 5364 -Annex C Medical Test Equipment ISO 5364 Test method for patency of lumen |
|
ISO 5364 Apparatus For Testing Resistance To Collapse Of The Buccal Portion |
|
IEC 61010-2-012-Figure 103 Scratching Tool Hard-soldered carbide tip K10 Material |
|
KP2021 Electrosurgical Unit Analyzer |
|
IEC 60601-2-2 Testing device for neutral electrodes |
Email to this supplier