mask bacteria filtration efficiency key performance indicators (BFE)
|
Detailed Product Description
1 summarize 1.1 Product introduction ZR - 1000 type mask bacteria filtration efficiency key performance
indicators (BFE) detector not only conforms to the requirements of
medical surgical masks technology YY0469-2011 appendix B in the
test method for filter efficiency (BFE) bacteria first B. 1.1 the
requirement of test instruments, but also conforms to the American
society for testing material ASTMF2100, ASTMF2101, the requirements
of the European EN14683 standards, innovative improvements were
made on the basis of this, with double pneumatic contrast sampling
method at the same time, improve the precision of sampling,It is
suitable for measuring and testing departments, scientific research
institutes, mask manufacturers and other relevant departments to
test the performance of mask bacterial filtration efficiency. 1.2 Product feature Negative pressure test system to ensure the safety of operators; Built - in peristaltic pump in negative pressure cabinet, A, B
two - way, six Andersen; The peristaltic pump flow can be set; The flow rate of bacteria-night spray of special microorganism
aerosol generator can be set. Good atomization effect; Embedded high speed industrial microcomputer control; 10.4 inches industrial high brightness color touch screen; USB interface, support U disk data storage; Cabinet built-in high brightness lights; Built-in leakage protection switch to protect the safety of
operators; Cabinet inner stainless steel whole processing molding, outer
plastic spray cold rolled plate,Heat preservation and flame
retardant between inner and outer layers; The front switch type glass door is convenient for the
experimenter to observe and operate.Detachable bracket, adjustable
bracket height; Supporting and moving dual purpose casters. 1.3 Execution standard Q/0212 ZRB003-2015 Mask bacterial filtration efficiency (BFE)
detector 1.4 Technical indicators main parameters parameters resolution Maximum permissible error Sampling flow of route A 28.3L/min 0.1L/min ±2.5% Sampling flow of route B 28.3L/min 0.1L/min ±2.5% Spray flow (8~10)L/min 0.1L/min ±5.0% Peristaltic pump flow (0.006~3.0)mL/min 0.001ml/min ±2.5% Front pressure of flow meter A (-20~0)kPa 0.01kPa ±2.5% Front pressure of flow meter B (-20~0)kPa 0.01kPa ±2.5% Spray flowmeter front pressure (0~300)kPa 0.1kPa ±2.5% Negative chamber pressure (-90~-120)Pa 0.1Pa ±2.0% Working temperature (0~50)℃ chamber negative pressure (-50~-200)Pa Data storage capacity >100000group Hepa filter characteristics Filtration efficiency of particles
above 0.3um≥99.99% Median mass diameter of aerosol generator Mean particle diameter
(3.0±0.3)μm,Geometric standard deviation≤1.5 Double-channel 6-stage Anderson sampler captures particle size
Ⅰ级>7μm,Ⅱ级(4.7~7)μm,Ⅲ级(3.3~4.7)μm,Ⅳ级(2.1~3.3)μm,Ⅴ级(1.1~2.1)μm,Ⅵ级(0.6~1.1)μm Fog chamber specifications (length600×diamter85×thick3)mm Total number of positive quality control sampler particles
(2200±500)cfu Ventilation flow rate of negative pressure cabinet ≥5m3/min Dimensions of negative pressure cabinet door (length1000×wide730)mm Size of the host (length1180×wide650×high1300)mm Stent size (length1180×wide650×high600)mm,Height adjustable within
100mm Working power AC220V±10%,50Hz Instrument noise <65dB(A) The weight About250kg Machine power consumption <1500W 7 Packing list Number Product Unit Quantity Remark 1 The host BFE test system set 1 2 Level 6 Anderson sampler pcs 2 3 spray pcs 1 4 stents set 1 5 carry handle pcs 4 6 Ac power cord pcs 1 3m 7 silicone tubeφ18x24 m 1 8 silicone tubeφ8x12 m 1 9 silicone tubeφ6x10 m 2 10 silicone tubeφ4x7 m 1 11 silicone tubeφ2.65x5 m 1 12 Product specification piece 2 13 Product certificate piece 1 14 Report on sprayer test piece 1 |
Product Tags: BFE mask bacteria filtration efficiency mask bacteria filtration efficiency mask bacteria filtration efficiency BFE |
Related Products
![]() |
25° Horizontal Angle Blankets Mechanical Strength Test Apparatus IEC60335-2-17 Figure BB.1 To BB.3 for Blanket Evaluation |
![]() |
Testing Blankets Mechanical Strength Test Apparatus IEC60335-2-17 Figure BB.1 To BB.3 with 33rpm/min Driving Sprocket Speed |
![]() |
IEC 60335-2-17 Blanket Spark Ignition Test Apparatus for Professional Testing |
![]() |
IEC 60335-2-40 Annex NN Flame Arrest Enclosure Verification Test For A2L Refrigerants |
![]() |
Blankets Mechanical Strength Test Apparatus IEC60335-2-17 Figure BB.1 To BB.3 |
![]() |
IEC 60335-2-17 21.103 Equipment For The Mechanical Strength Test For Blankets |
Email to this supplier