Programmable IPX3 / IPX4 Rain Spray Chamber / Waterproof Oscillating Tube Spray Tester
|
Programmable IPX3/IPX4 Rain Spray Chamber Waterproof Oscillating Tube Spray Tester
Technical Performance Main technical parameters:In accordance with IP 3.4
Structure Material:
Protection Device:
Features: 1. The material of the outer box is made of high quality (t = 1.2mm) A3 steel plate CNC machine tool forming, shell surface spray treatment, more smooth, beautiful; 2. Inner material of chamber: Imported high grade stainless steel (SUS304); 3. Insulation material: Rigid polyurethane foam + glass fiber; 4. Rotary table: PVC hard board (corrosion-resistant); 5. The parts contact with water all are stainless steel or copper material; 6. Control system optional simple programming controller or hot technology independent development of full-color touch control system; 7. Control interface friendly, simple operation, operation stable, low noise design, low carbon energy saving; 8. Swing tube with stepper motor drive, accurate angle, the swing rate can be set and adjusted, each group of nozzles are the center of the turntable radiation, the test is completed automatically compressed air to clean water stains; 9. Original nozzle, water column does not spread, and with angle adjustment device. 10. Automatic lift water surface function; 11.Germanyoriginal high-pressure pump, jet-type heating device; 12. To prevent the impurities in the water plug the nozzle, equipped with water quality filtration system; 13. large area of visualization of glass doors, easy to observe the measured samples in test box;
Related test standards: 1, GJB150.8 rain test method 2, Water resistance test method GB2423.38 3, IEC60068-2-68 Water resistance test method 4, GB4208 water resistance test method 5, IEC60529 water resistance test method 6, GB / T4942.1 water resistance test method 7, IEC60034-5 Water resistance test method 8, ISO 20653 Water resistance test method
Operation Environment:
2.Environmental temperature:15°~40℃ 3.Relative humidity:<70%R.h
Structure and Principal The enclosure of test cabinet and studio is made up of high-end short plate and 304B stainless steel.Its cabinet consist of main body,transmission and electrical part. Principal description: Achieve test objective through mechanical transmission.turntable transmission mechanism achieves specified rotational speed through worm and worm gear driven by motor.That speed reducer reduce driven by motor and then rack bar drives ring gear makes pendulum move. Machine structure:whole set Face Plate
Usage
Login Page
Home Page
5.Enter the operation interface;click the stop key to stop the test.Click Home position return and set parameters to begin the second test.
Operation Figure Note:Only after IP3 test stops can user start IP4 test,so please stop IP3 if starting IP4 in case of breakdown.
Operation Methods: 1.Turn on the general power 2.Click start button 3.Set up touchscreen’s parameters. (1)Main menu is displayed on touchscreen when power is on. (2)Set parameters in menu. (3)Press start button to start operation. Cut off the general power when back to the control interface after test finishes. Precautions for Use 1.refuel the transmission mechanism periodically.refuel cleansing 20# machine oil to speed reducer. 2.If hearing abnormal noise during operation,pleasestop to find out faults.Restartif after fault elimination in case of reducing service life. 3.After device positioning,prop up the resting support in case that castor translocate because of vibration. 4.If the blowhole is blocked,remove the pipe and rinse it thoroughly under running water and assemble to it.
|
||||||||||||||||||||||||||||||||
Product Tags: temperature and humidity chamber climatic test chamber IPX4 Rain Spray Test Chamber |
![]() |
Environmental Test Chamber with -80℃ to +200℃ Temperature Range |
![]() |
IP34 Automatic Environmental Test Chamber 80-150KPA Spray Pressure |
![]() |
50±5% Humidity Range Carbon Arc Lamp Weathering Test Chamber with Electric Control Gate Temperature Control Method |
![]() |
Xenon Lamp Weathering Test Chamber 4KW Power ≤±2C Temperature Deviation for Accurate Testing |
![]() |
Adjustable Ultraviolet Wavelength Aging Test Chamber with Imported Type Lamps and Adjustable Irradiation Intensity |
![]() |
Powerful Ventilation Aging Test Chamber with Test Stand Speed 8-10rpm 1-10rpm and Power Supply 102W220V 60HZ 50HZ |