Zhaga book 18 Annex B Mechanical Mechanical Stop Gauge / Contact Making Gauge
|
Zhaga book 18 -Annex B Mechanical drawing of the Mechanical-stop-gauge
5.1.1 Mechanical-stop-gauge The Mechanical-stop-gauge is defined in Annex B. This gauge is used to verify whether the mechanical stop features of the LEX-M under test (see Figure 3-6) can withstand a torque of 5 Nm.
Zhaga book 18-Annex C Mech. drawing of the Contact-making-gauge-min and Contact-making-gauge-max
5.2.1 Contact-making-gauge-min The Contact-making-gauge-min is defined in Annex C. This gauge is used to verify whether the LEX-R under test can mate with a LEX-M that is compliant with this specification and whether all contacts of the LEX-R under test make electrical contact with all contacts of a LEX-M that is compliant with this specification 5.2.2 Contact-making-gauge-max The Contact-making-gauge-max is defined in Annex C. This gauge is used to verify whether the LEX-R under test can mate with a LEX-M that is compliant with this specification and whether all contacts of the LEX-R under test make electrical contact with all contacts of a LEX-M that is compliant with this specification
Zhaga book 18-Annex D Mechanical drawing of the Un-mating-torque-gauge
5.2.3 Un-mating-torque-gauge The Un-mating-torque-gauge is defined in Annex D. This gauge is used to verify whether after 5 mating cycles of the LEX-R under test with the gauge the torque for un-mating is 1.0 Nm or more |
Product Tags: Iec 60061 3 Go And Not Go Gauge |
![]() |
E12 lamp cap gauge|7006-28C-1 |
![]() |
GU10 7006-21A-2 Lamp Cap Gauge For Checking Maximum Insertion And Withdrawal Torques In Lampholders |
![]() |
E27-7006-22C-1 Gauge I For Checking Side-Contact Resiliency In Lampholders |
![]() |
E40 Lamp cap gauge|7006-28D-1 |
![]() |
E40 Lamp cap gauge | E40-7006-27-7 | E40-7006-28D-1 | E40-7006-52-1 | E40-7006-53-1 |
![]() |
ANSI C81.63 Threaded Gauge For Testing Lampholders |