High Effective Blowing Dust Test Chamber Customized 3700 X 1600 X 2100mm
|
Blowing Dust Test Chamber KP-DCJB1000
Purpose Dust (< 150 µm) procedure. This test is performed to help evaluate the ability of materiel to resist the effects of dust that may obstruct openings, penetrate into cracks, crevices, bearings, and joints, and to evaluate the effectiveness of filters
Standard MIL-STD-810G.
Design principles Its structure is a funnel,a collecting hole for dust on the bottom,on the right side of this hole is equipped with a suction inlet of turbine circulating fan.Send the pumped dust into the bottom of inner chamber and then to the left side and go upwards;blow the dust into test chamber from the left side; the dust should be blown rightwards in a horizontal direction and then begin circulation Material 1. Material: SUS304 stainless steel plate 3. Chamber door with a large observation window 4. Unique duct design, to ensure the concentration of laminar flow laminar flow 5. Basic structure: Pre-treatment box, test chamber, vacuum port, dust box, circulating dust device, vacuum system, dust tank, flow valve, heating system, backflow vane, sample carousel, screen, concentration meter And so on.
Technical Parameters 1, Model: KP-DCJB1000 2, studio size (mm): 1000X1000X1000mm (W × D × H) 3, Dimensions (mm): 3700X1600X2100mm (W × D × H) 7, dust: diameter <150μm; 8, inside the chamber, the dust concentration in the pipeline is 10.6G / m³ ± 7G 9, airflow speed: 8.9m / s ± 1.5 (adjustable) 10,Dust Composition:CaCO 3 , MgCO 3 , MgO, TiO 2 : 5% Ferric oxide (Fe 2 O 3 ) : 10±5% Aluminum oxide (Al 2 O 3 ):20±10% Silicon dioxide (SiO 2 ):remaining percentage (50 to 80 %) 11, temperature: 23-80C ° 12, the rate of temperature change: ≥ 3C ° 13, function: blowing dust, blowing sand, dust falling (high temperature operation) 14, environmental requirements: 22 ℃ ± 3. 15, power supply: 380V 3Phase, power: 15KW 50HZ
Control System 1. PLC and touch screen intelligent control system 2. PT100 test sensor 3. Sand and dust concentration meter 4. Anemometer (hand-held) to adjust the wind speed before testing. 5. Instrument over-temperature protection 6. Power phase loss protection 7. Leakage circuit breaker 8. Power: AC380 V 50Hz 9. Door: tempered glass door 10. Vacuum pump 60-600L / H 11. Regulating valve, nozzle, pressure regulator 12. Controller: Adopt programmable controller (this controller has many kinds of arbitrarily setting control functions as below) a. blowing dust time (stop, blow) h/m/s adjustable b. Cycle time: adjustable c. Default test time: 0s ~ 999h99m99s adjustable d. Power on: off - on - off
|
Product Tags: Dust Testing Equipment Sand And Dust Test Chamber |
![]() |
JIS-D0207-F2 Sand Dust Test Chamber |
![]() |
Dust Test Chamber As Per IEC 60529/ Sand And Dust Chamber As Per Iec 60529 |
![]() |
IEC 60529 IP5X6X Dust Test Chamber / Environmental Testing Machine |
![]() |
Large Environmental Simulation Tester Climate Test Equipment With Wide Temperature Range -70~180℃ |
![]() |
IEC60529 IPX5 IPX6 Laboratory Sand And Dust Resistance Test Chamber |
![]() |
IP Class Sand And Dust Proof Chamber For Indoor Low Concentration Dust Pollution Testing |