New Type Network Tester RJ45 RJ11 LAN Cat 5 5e Cat 6 Network
Telephone Cable Tester Description: This LAN Network Cable Tester is requisite and needful in network
installation and maintenance. Cable Tester for RJ-11, RJ-45, CAT5, CAT5e, 10/100BaseT,
TIA-568A/568B, AT&T 258-A RJ45 Network Cable Tester test correspondingly double-twisted
cables 1, 2, 3, 4, 5, 6, 7, 8 and Ground 9 LED lights to indicate wiring connection on both remote and
master unit With this RJ12 Network Cable Tester, you can judge wrong
connection, short circuit and open circuit Detachable remote tester, test remote cable up to 1000ft. in length Auto scanning function for rapid testing Powered by one 9V battery (included) Compact and light weight RJ11 Network Cable Tester, very practical
for home and outside use
1. It can test correspondingly double-twisted cables
1,2,3,4,5,6,7,8 and G,meanwile,can judge wrong connection,short
circuit and open circuit. | 2. Switch ON shows the normal grade,S is slow automatic grade,M is
manual. |
II. Test of double-twisted cables: Switch on the power,and put cables into both main tester and
remote tester.The lights of the main tester will turn on equently
from 1 to G. | Main Tester: | | 1-2-3-4-5-6-7-8-G | Remote Tester: | | 1-2-3-4-5-6-7-8-G(RJ45) | | 1-2-3-4-5-6------(RJ12) | | 1-2-3-4----------(RJ11) |
Following are erroneous connections: | 1. If one cable, for example cable No.3 is open circuited, the two
No.3 lights of the main tester and remote tester will not turn on. | 2. If several cables are not connected, several lights will not
turn on respectively. If less than two cables are connected ,none
of the lights is on. | 3. If two ends of a cables is disordered, for example No.2 and
No.4,then displays on: | | Main Tester: | | 1-2-3-4-5-6-7-8-G | Remote Tester: | | 1-4-3-2-5-6-7-8-G | | 4. If two cables are short circuited, neither of the corresponding
lights is on of the remote tester while main tester remains
unchanged. If three cables, including three, are short circuited,
none of the corresponding lights is on. |
| III. If test patch panels or wall plate outlets, two cables which can
match with other (eg 110P4 and RJ45)will ne connected to the
tester. | | IV. If test cables of the same axes,BNC turns on when the cables
works. |
|
|