Telecommunication MDF Main Distribution Frame Over - Current Protector Unit
|
|
Main Distribution Frame Over-current Protector Unit
1. Perfect and reliable over-voltage and over-current protection with sound and light alarm, and self resulming fail protection. 2. The performance of anti-burn: PPT(UL94V-0) or anti-burn ABS(UL94V-0), combustibility achieved GB/T 5169.7-1985 standard 3. DC puncture voltage: 190-260V 4. Pulse puncture voltage: ≤800V(1KV/us voltage increasing rate) 5. Insulation resistance: 1000MΩ(between any two separable modules) 6. Normal temperature resistance: ≤22Ω(R≤2Ω(over-current protection) 7. Contact resistance: ≤3mΩ 8. Contact resistance between reeds: ≤7mΩ 9. Normal temperature current: I=falling from 500mA to 150mA t<20s I=falling from 1A to 500mA t<1.3s I=falling from 2A to 500mA t<0.5s I=falling from 3A to 500mA t<0.2s 10.Sactive time: I=2.5A t<15s(220V/AC) 11.resistance to voltage: ≥1000V(AC)/1min without breakdown or arc
1, The frame is made of shaped alloy aluminum , it looks nice in shape and construction; 2, Perfect and reliable over-voltage and over-current protection with sound and light alarm, and self resulming fail protection. 3, Both security block and test block are equipped with dualclip, terminals, when cutover outside lines mat be not disconnected, clipping wires and cutting lines will be finished at the same time, the connecting is quick and reliable. 4, The performance of anti-burn: PPT(UL94V-0) or anti-burn ABS(UL94V-0), combustibility achieved GB/T 5169.7-1985 standard 5, DC puncture voltage: 190-260V 6, Pulse puncture voltage: ≤800V(1KV/us voltage increasing rate) 7, Insulation resistance: 1000MΩ(between any two separable modules) 8, Normal temperature resistance: ≤22Ω(R≤2Ω(over-current protection) 9, Contact resistance: ≤3mΩ 10, Contact resistance between reeds: ≤7mΩ 11,Normal temperature current: I=falling from 500mA to 150mA t<20s I=falling from 1A to 500mA t<1.3s I=falling from 2A to 500mA t<0.5s I=falling from 3A to 500mA t<0.2s 12,Sactive time: I=2.5A t<15s(220V/AC) 13,resistance to voltage: ≥1000V(AC)/1min without breakdown or arc 14,Clip-on life: >200 times
|
| Product Tags: intermediate distribution frame optical distribution frame |
|
High Density for Both Vertical / Horizontal InstallationJPX202-STO 128 Pairs Exchange Side Terminal Block Test Module |
|
High Density 100 Pairs Cable Side Terminal Block with Voltage and Current Protection for MDF Main Distribution Frame |
|
16 Systems DDF E1 120ohm MPX286 Unit For Country Markets |
|
SUNSEA D19-B32-E1 19inch 120 Ohm 16 Systems 32 System Unit Digital Distribution Frame DDF |
|
75 Ohm Digital Distribution Frame DDF 8 System |
|
Digital Distribution Frame with 120 Ohm Impedance for Digital Signals Transfer MDF Main Distribution Frame |
