Miniature Flange Mounted Tension Compression Sensor FFJ is made of
stainless steel utilizing strain gauge technology intended for both
tension and compression force measurement, high accuracy with
maximum 0.1% non-linearity of the full scale. Micro Cylindrical
Load Cell FFJ offers 0-5kg / 0-10kg / 0-20kg / 0-30kg / 0-50kg
(0-50N / 0-100N / 0-200N / 0-300N / 0-500N) five rated capacities
to choose from. One end with flanged surface, the other end with M3
threaded hole,which makes miniature force transducer FFJ can be
easily mounted to mechanical parts and get force measurement done.
Stainless steel construction, compact size, bidirectional force
measurement, high accuracy, Column Type Force Sensor FFJ offers a
perfect mixture for applications such as wire tension control,
force distribution analysis, automated control, cylinder thrust
measurement, assembly force monitoring, spring testing, connector
insertion and extraction force measurement and so on. In addition
to the standard specifications, Forsentek is also capable of
providing custom design service to meet requirements of different
applications.
Dimensions
Ordering code | Measurement Range | Force direction |
FFJ-50N | 0-50N / 0-5kgf | Tension and compression |
FFJ-100N | 0-100N / 0-10kgf |
FFJ-200N | 0-200N / 0-20kgf |
FFJ-300N | 0-300N / 0-30kgf |
FFJ-500N | 0-500N / 0-50kgf |
Specifications
Capacity | 50N / 5kgf / 11lb 100N / 10kgf / 22lb 200N / 20kgf / 45lb 300N / 30kgf / 67lbs 500N / 50kgf / 112lbf |
Rated output | 2.0 mV/V |
Excitation | 3-15V |
Zero balance | ±0.1mV/V |
Nonlinearity | ±0.1% of the capacity |
Hysteresis | ±0.1% of the capacity |
Nonrepeatability | ±0.05% of the capacity |
Creep(5min) | ±0.05% of the capacity |
Safe overload | 150% of the capacity |
Ultimate overload | 200% of the capacity |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.02% R.O./oC |
Temperature shift span | ±0.02% R.O./oC |
Input resistance | 385±30 ohms |
Output resistance | 350±10 ohms |
Insulation resistance | >5000M ohms |
Ingress protection | IP50 |
Material of element | Stainless steel |
Cable | Ø3*3000mm 4-core shielded |
Wiring code | Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
Flange Mounted Load Cell 500N 300N 200N 100N 50N Tension
Compression Sensor
A Force Sensor is a transducer that converts mechanical load into
mV signal proportional to the applied force.The acting force causes
deformation of the measuring element,the bonded strain gage deforms
accordingly which will cause the resistance change of the
wheatstone bridge,under constant power supply, the output signal
between Sig+ and Sig- will change proportionally,thus the
load/force can be measured by measuring the output signal from the
transducer.
Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output of Micro Force Sensor FFJ is around 2.0mV/V.
Power supply of Miniature Column Type Force Transducer FFJ is
normally within 3-15V.
Load / Capacity is within 0-1.
So the output range of Miniature Tension Compression Sensor FFJ is
normally within -30mV...+30mV for bidirectional force
measurement.
Example one: Miniature cylindrical traction/compression load cell
FFJ-100N with 2.0mV/V sensitivity powered by 5V DC,the output range
is -10mV...+10mV.
Example two: Micro Column Type Compression And Traction Force
Sensor FFJ-50N with 2.0mV/V sensitivity powered by 10V DC,the
output range is -20mV...+20mV.
A signal conditioner can be used with force transducer FFJ to
deliver -5~5V, 0-10V or 4-20mA output.
Example one: Miniature tension compression load cell FFJ-100N
working with 4-12-20mA amplifier,the Force-Current relationship
will be 0-100N compression load VS 12-20mA output, 0-10kg traction
load VS 12-4mA output, which is linear regardless of the
measurement error. Namely 12mA output corresponds to “0” load,
12.8mA output corresponds to 10N compressive load, 8mA output
corresponds to 50N tensile load, and so on.
Example two: Miniature Compression Traction Load Cell FFJ-50N
working with -5-5V amplifier,the Force-Voltage relationship will be
0-50N compression load VS 0-5V output,0-50N traction load VS
0-(-5V) output, which is linear regardless of the measurement
error. When you get 1V output,it means the current load is 10N
compression force,when you get -2V output,it means the current load
is 20N tensile force,and so on.