XJ-50Z Computer Control Non-metal Material Charpy & Izod Impact
Testing Machine
1.Applications:
This machine is mainly used for impact toughness test of plastics,
GFPA, FRP, ceramics, cast stone,
plastic electrics, electrical insulating material and other
non-metal materials.
This machine is applicable to the Scientific research colleges and
universities authority,nonmetallic
material factory, and other test labs and inspection department for
testing.
This machine with wide range of impact energy. Izod and charpy can
be in common use.
Simple structure, easy operation and high test accuracy.
Charpy Impact and Izod Impact, can be arbitrarily selected and
combined the each of energy pendulum.
Computer control, print test report, and storing historical data.
2.Standard:
2.1 | GB/T 1043-93 | Hard plastics charpy impact testing method. |
2.2 | GB/T 1843-1996 | Plastics izod impact testing method |
2.3 | JB/T 8761-1998 | Plastics izod impact testing machine. |
2.4 | JB/T 8762-1998 | Plastics charpy impact testing machine. |
2.5 | ISO 179-1993(E) | Plastics-measuring of charpy impact strength. |
2.6 | ISO 180-1993(E) | Plastics--measuring of izod impact strength. |
2.7 | GB/T 18743-2002 | Thermoplastic plastic pipe for fluid delivery charpy impact test
method. |
2.8 | ASTM D256 | Plastics anti izod impact testing method. |
3.Technical Parameter:
A.Charpy Impact Testing:
Impact Speed | 2.9m/s and 3.8m/s |
Pendulum Energy | 1J, 2J, 4J, 5J, 7.5J, 15J, 25J, 50J |
Pendulum Center To Sample Center Distance | 221mm, 380mm |
Rising Angle Of Pendulum | 160° |
Pendulum Movement | Pd1=0.5155N.m | Pd2=1.0311N.m |
Pd4=2.0622N.m | Pd5=2.5777N.m |
Pd7.5=3.8662N.m | Pd15=7.7324N.m |
Pd25=12.8888N.m | Pd50=25.777N.m |
Jaw Length | 85mm |
Supporting Distance | 40mm, 60mm, 70mm, 95mm |
Supporting Blade Corner Radius | R=1mm |
Impact Blade Angle | 30° |
Impact Cutting Edge Radius | R=2mm |
Specimen Type And Supporting Distance (mm) | Specimen Type | Length | Width | Thickness | Supporting Distance | Jaw Model |
1 | 80±2 | 10±0.5 | 4±0.2 | 60 | A |
2 | 55(50)±1 | 6±0.2 | 4±0.2 | 40 | B |
3 | 120±2 | 15±0.5 | 10±0.5 | 70 | C |
4 | 125±2 | 13±0.5 | 13±0.5 | 95 | D |
B.Izod Impact Testing:
Impact Speed | 3.5m/s |
Pendulum Energy | 1J, 2.75J, 5.5J, 11J, 22J |
Rising Angle Of Pendulum | 160° |
Pendulum Impact Center To Impact Blade Distance | 322mm |
Pendulum Movement | Pd1=0.5155N.m | Pd2.75=1.4177N.m |
Pd5.5=2.8355N.m | Pd11=5.6711N.m |
Pd22=11.3419N.m | |
Impact Blade To The Plane Of The Jaw Distance | 22mm |
Blade Corner Radius | R=0.8mm |
Sample Type Meet The Standard GB1843-80, ISO 180-82. |