IEC 60695 Needle Flame Test Chamber

IEC 60695 Needle Flame Test Chamber

Minimum Order Quantity 1
Delivery Time 25 working days
Place of Origin China
Supply Ability 15 sets/month
Packaging Details Standard Export Package
Certification CE, CO, Rosh, Form E, Calibrate Certificate
Brand Name SKYLINE
Model Number SL-F11
Price Negotiable
Detailed Product Description
IEC 60695 Needle Flame Test Chamber
Electronic Product Flame Test Apparatus, IEC 60695 Needle Flame Test Chamber
Introduction
The Needle Flame Test Chamber evaluates fire resistance caused by internal faults such as leakage current in cables, wires, and similar components. This apparatus complies with Chinese GB4706.1, GB5169.5, IEC60695-2-2, and IEC61347-1 standards.
Applications
• Electrical and electronic products
• Components and accessories of household appliances
Key Features
  • All stainless steel and brass construction
  • Automatic burner ignition system
  • Digital displays for temperature and test timing
  • Large viewing window for convenient observation
Technical Specifications
ParameterSpecification
Needle BurnerInner hole diameter Φ0.5mm ± 0.1mm, Diameter ≤Φ0.9mm, length ≥35mm, stainless steel
Burner Angle0~45° (adjustable for flame height)
ThermocoupleØ0.5mm Type K (Ni/Cr - Ni/Al), armored sheath withstands 40°C~1100°C
Burning Time0-999.9s ± 0.1s adjustable (typically 30s)
Hold Burning Time0-999.9s ± 0.1s, automatic recording, manual timeout
Flame Height12mm ± 1mm (with height measurement instruments)
Flame GasButane gas, minimum 95% purity (bottled lighter gases acceptable)
Temperature Test Range0~1000°C
Flame Temperature RequirementsFrom 100°C ± 2°C to 700°C ± 3°C in 23.5 seconds ± 1 second
Standard Copper Block4mm ± 0.01mm, weight 0.58g ± 0.01g before drilling, Cu-ETP
Test ProcessAutomatic control with independent convulsions
Chamber≥0.5m³
Control SystemSingle chip microcomputer + touch screen control
Applicable StandardsGB/T5169.10-2006, IEC60695-11-5:2000, UL746A
Power Supply800VA, 220V, 48-60Hz
Display Panel LanguageEnglish (customization available)