Fire Testing Equipment Steiner Tunnel Test Apparatus
|
Steiner Tunnel Test ApparatusProduct introductionUL910 covers the test method for determining values of flame-propagation distance and optical smoke density for electrical and optical-fiber cables that are intended to be installed in ducts, plenums, and other spaces used to transport environmental air without the cables being enclosed in raceways in those spaces. Technical parameters 1.The fire test chamber is exactly the same as that of UL fire lab. Product Feature and Application1. The stainless steel combustion test box body has a brick
structure inside, which can resist the flame impact and has good
thermal insulation performance; Product DetailsUL910/NFPA262 Steiner horizontal tunnel furnace is mainly used for the flame retardant performance test of CMP grade wire and cable. It is mainly used for cables in horizontal subsystems that are directly laid in ventilation or forced ventilation without metal pipelines. The flame retardant test standard represents the most stringent flame retardant test standard for UL and even the entire wire and cable flame retardant test. Only the fluorine material sheath cable can pass the flame retardant test method. Due to the high decomposition temperature of fluoroplastics (greater than 400 degrees), the ignition point is also high (800 degrees or more), and it is not easy to burn when the fire is not strong, so it has better fire resistance than other organic materials. The purpose of this test is to determine whether the flame-propagation and smoke-generating characteristics of cables without raceways are within the limits specified in the National Electrical Code (NEC). Cables having adequate fire-resistant and low-smoke-producing characteristics need not comply with general wiring methods when the cables are installed (without raceways) in environmental-air ducts, concealed hollow building spaces used as ducts for environmental air, and other environmental-air-handling spaces not specifically excluded (areas involving grease and flammable dust, vapor, and the like). This test method is essentially the same as the test method described in the Standard Method of Test for Fire and Smoke Characteristics of Wires and Cables, NFPA 262. Application:It is mainly used for cables in horizontal subsystems that are directly laid in a ventilated or forced air environment without using metal pipelines. Standards:NFPA 262 UL910 Dimension:21300 mm (L) x 1100 mm (D) x 2100 mm (H) Installation requirements Electrical: 380 Volts AC, 20KW Ambient Temperature: Operating 15°C to 35°C. Steiner Tunnel Test Apparatus.pdf What does the Steiner tunnel test assess? Steiner Tunnel tests measure the surface burning characteristics of interior finish materials and assemblies used in buildings, which is critical to understanding how materials react during a fire. |
Product Tags: flammability test apparatus flammability testing labs |
![]() |
ISO 5660 AC220V Cone Calorimeter For Building Materials Testing |
![]() |
IEC 60331 Cable Circuit Integrity Fire Resistance Test Machine BS 6387 Cable Fire Resistance Test Equipment |
![]() |
UL910 Steiner Tunnel Furnace chamber |
![]() |
PC control model ISO 5657 Building Materials Ignitability Flammability Tester |
![]() |
ISO 5657 Building Materials Ignitability Flammability Tester |
![]() |
ISO 9150/BS EN 348 Protective Clothing Molten Metal Splashes Impact Resistance Tester |