Wire and Cable Vertical Horizontal Burning Test Machine
Experimental principle
This machine is suitable for the flammability test of various wire
and cable insulation coating materials, printed circuit board
materials, IC insulators and other organic materials. During the
test, the test piece is placed on the top of the flame, burned for
15 seconds, extinguished for 15 seconds, repeated After 5 times,
the test piece is incinerated, and the burning, extinguishing time
and repetition times can be set, and the operation can be performed
automatically.
Technical parameters
1. Vertical combustion chamber: It is made according to the
standard size of UL1581, and the internal size is 305*355*610mm.
2. Horizontal combustion box: It is made according to the standard
size of UL1581, and the internal size is 305*355*610mm.
3. Vertical spark nozzle: The nozzle angle is 20 degrees with a gas
control valve.
4. Horizontal spark nozzle: The nozzle angle is 90 degrees with a
gas control valve.
5. Vertical or horizontal nozzle selection mode.
6. Select manual/auto mode.
7. When the preset data is reached, the machine will automatically
stop the test.
8. Fuel: gas. methane (customer-owned)
What is a test fire and why is it important?
What Is Fire Testing? Fire testing intends to understand the
influence of a direct flame on a material or product. Companies may
analyze the effect on wiring or cable, building materials or
furnishings.