China Lab Testing Equipment manufacturer
SKYLINE INSTRUMENTS CO.,LTD
Skyline Instruments Co.,LTD We only manufacture Lab Testing Equipment
9
Home > Products > Fire Testing Equipment >

IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester

IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester

Brand Name SKYLINE
Model Number SL-7603C
Certification CE
Place of Origin China
Minimum Order Quantity 1 unit
Price negotiated
Payment Terms T/T, L/C, Western Union, MoneyGram
Supply Ability 1 unit/ month
Delivery Time 10 working days
Packaging Details Plywood case
Standards IEC60332-1-1:2004
Vertical burning chamber W300xH1200xD450mm
Length of specimen 600±25mm
Gas flow range 0.1-1L/min
Detailed Product Description
IEC60695-11-03 Single Cable Vertical Flammability Tester 
 

Product introduction

Single Cable Combustion Tester is the most widely used and lower cost of cable fire performance test equipment, which can meet the standards IEC 60332-1-1:2004 in the provisions of technical indicators and requirements. Single cable combustion Tester is used to test the flame retardant property of the cable's insulating layer under abnormal conditions such as overheat and overcurrent. It can be used in vertical cable or fiber flame spread test, also can be test the state of flaming droplets during combustion.

 
Application
Applies to check thesingle insulation wire and cable vertical spreading test which total section area less than 0.5mm2
 
Standards
According to IEC60332-1-1:2004, IEC60332-1-2:2004,  IEC60332-1-3:2004, EN50265-1, EN50265-2-1
 
Main parameters
 Vertical burning chamber W300xH1200xD450mm
 Gas Use high purity propane gas or liquefied petroleum gas (provide by user-self)
 Specimen length 600±25mm
 Area of specimen Total section area less than 0.5mm2
 Testing temperature This device is located in a stuffiness room and the temperature keeping the 23±10℃ for testing
 Burning time continuously setting between 0.1-999.9S, during the setting time flame could continuously burning the specimen
 Control function Switch can choose to be manual or automatically according to the actual needed
 Gas flow range 0.1-1L/min
 Area flow range 0.1-1m3/h
 Burner 500W for standards power, 125±25mm for total height of the flame
 Temperature measurement system according to GB/T5169.14-2007 and IEC60695-11-03 standard requirements, including temperature copper (10g), K type thermocouple and diameter is 0.5 mm with stainless steel sheathed, stopwatch and thermometer etc.

 

Automotive Single Wire.pdf

What is a Vertical flame Test?
A test specimen is positioned vertically above a controlled flame and exposed for a specified period of time. Following exposure, the flame source is removed. Measurements are made on the length of time that the specimen continues to flame and the time afterglow continues after the flame source has been removed.
What is the flame exposure test for a cable?