ATD020 Portable Peltier Thermoelectric Dehumidifier / Peltier
Condenser
Please contact Adcol for detailed specifications.
Mechanical Clamping Method
The following is a list of guidelines for using mechanical
clamping:
1. The mounting surfaces (between which modules are to be clamped)
should be flat to within 0.001”. 2. Mounting and module surfaces
should be carefully cleaned to remove any grit, burrs, etc. 3. If
more than one module is to be used in the assembly, all modules
should be within 0.001” in height. 4. Use graphite pads as the
thermal interfaces on both hot and cold sides. While not as
conductive as thermal grease initially, over time it is the better
alternative. 5. Bolt the object to be cooled and heat sink together
using stainless steel fasteners with washers or split type
lockwashers. Tighten each side a little bit at a time, alternating
between screws, to insure an even pressure across the module
surface. Maximum recommended compression loading is 350 lbs. per
sq. inch of module surface.