China Peltier Thermoelectric Cooler manufacturer
Adcol Electronics (Guangzhou) Co., Ltd.
Adcol Electronic (Guangzhou) Co., Ltd.
9
Home > Products > Thermoelectric Air Conditioner >

Customized Peltier Thermoelectric Cooler Air To Air For ATM Machine

Customized Peltier Thermoelectric Cooler Air To Air For ATM Machine

Brand Name Adcol
Model Number ATA - C200 - 24VDC
Certification ISO9001 , CE
Place of Origin China
Minimum Order Quantity 1pcs
Price Negotiation
Payment Terms T/T , Paypal
Supply Ability 500Pcs per month
Delivery Time 3 - 4 Weeks
Packaging Details Solid Carton Packaging
Power 170W
Cooling Capacity 120W
Running Current 7.0A
Startup Current 8.2A
Nominal Voltage 24VDC
Max Voltage 27.2VDC
Detailed Product Description

Customized Peltier Thermoelectric Cooler Air To Air For ATM Machine​

The ATA PowerCool Series is an Air-to-Air Thermoelectric Assembly (TEA) that uses
impingement flow to transfer heat. It offers dependable, compact performance by cooling
objects via convection. Heat is absorbed and dissipated thru high density heat exchangers
equipped with air ducted shrouds and brand name fans. The heat pumping action is created
by thermoelectric modules, which are custom designed to achieve a high coefficient of performance (COP).


Features
Compact design
Reliable solid-state operation
DC operation
RoHS compliant
IP55(IEC 60529)

Product design with IEC60950 Standards

Performance Data

 

Power (W)170
Cooling Capacity(W)120
Running Current(A)7.0
Startup Current(A)8.2
Nominal Voltage(VDC)24
Max Voltage(VDC)27.2
Operating Temperature(℃)-10~70
Storage Temperature(℃)-40~85
Weight(KG)4.5
MTBF(fan-hrs)70000
Performance Tolerance10%


Controller:

 

Temperature setup:


Cooling:Ton=20-40℃ Toff= 10-25℃

 

Reliability Assurance

※Operation conditions Requirements

Operation Condition: ETS 300 019-1-4,CLASS 4.1E

Operating Temp: -10~70℃

Testing standard: ETS 300 019-2-4, Class 4.1E

※Storage requiremengs

Storage condition:According to ETS 300 019-1-1,CLASS 1.2

Testing standard: ETS 300 019-2-1,CLASS 1.2

※IP protection requirements

Condition: The outer Fans must meet IP55 rate

Testing standard: IEC 60529

※Corrosion resistance requirements
 

Outer side of the TEC cooler must be meet:

ItemTesting MethodTesting conditionsTesting cycle
Alternate hot and humidIEC 68-2-30

High Temp:55℃

Other standard according to IEC 68-2-30

10 C
Alternating salt fogIEC 68-2-52IEC 68-2-52 Class 210 C
Molds experimentIEC 68-2-10

GB/T2423.16 Test method 1

IEC 68-2-10

28days

 

Any metal products cannot be showing signs of corrosion and other significant damage of the coating or plating

Product cannot appear any functional deterioration after testing

※Safety

1. meet IEC 60950-1/EN 60950-1

2. Hi-pot testing: 1500VDC/10mA/5s

Product Tags: industrial air conditioner   outdoor air conditioner  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Adcol Electronics (Guangzhou) Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)