China Drug Abuse Test Kit manufacturer
Orient New Life Medical Co.,Ltd.
Orient New Life Medical Co.,Ltd. Quality is life.
9
Home > Products > Infectious Disease Blood Tests >

High Accuracy One Step TP (Treponema Pallidum) Rapid Diagnostic test strip. blood test

High Accuracy One Step TP (Treponema Pallidum) Rapid Diagnostic test strip. blood test

Brand Name New Life
Certification ISO13485,
Place of Origin China
Minimum Order Quantity 5000pcs
Price USD0.1-USD1
Payment Terms T/T, Western Union
Supply Ability 10000000pcs/month
Delivery Time 20-30days
Packaging Details 1pc/pouch, 25pcs/box
Category Disease
Format Strip/cassette
Specimen Whole Blood/Serum/Plasma
Testing time 5-15 minutes
Shelf Life 24 Months
Application Treponema Pallidum
Accuracy 99.44%
Detailed Product Description

High Accuracy One Step TP (Treponema Pallidum)  Rapid Diagnostic test strip. blood test

 

 

Product Name:


Syphilis Rapid Diagnostic test strip

 

 

Intended Use:

 

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Treponema Pallidum (TP) in whole blood, serum or plasma to aid in the diagnosis of Syphilis.

 

 

Test Principle:

 

 

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) is a qualitative membrane based immunoassay for the detection of TP antibodies (IgG and IgM) in whole blood, serum or plasma. In this test procedure, recombinant Syphilis antigen is immobilized in the test line region of the test. After specimen is added to the specimen well of the device, it reacts with Syphilis antigen coated particles in the test. This mixture migrates chromatographically along the length of the test and interacts with the immobilized Syphilis antigen. The double antigen test format can detect both IgG and IgM in specimens. If the specimen contains TP antibodies, a colored line will appear in the test line region, indicating a positive result. If the specimen does not contain TP antibodies, a colored line will not appear in this region, indicating a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.

 

 

 

TEST PROCEDURE

 

1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open pouch until ready to perform the assay.

 

2. Remove the test device from the sealed pouch. Lay it on a flat, clean and dry surface.

 

3. Use the pipette to draw and slowly add 1 drop of whole blood/serum/plasma to the sample well.

 

4. Hold the buffer vertically and add 1 drop to the sample well. /If using a pipette, change a new one to avoid cross-contamination. Draw and transfer 2 drops of buffer to the sample well.

 

5. Interpret test results within 10-15 minutes. Do not interpret after 20 minutes.

 

Caution: The above interpreting time is based on room temperature range of 15-30℃. If your room temperature is significantly lower than 15℃, then the interpreting time should be properly increased to 30 minutes.

 

 

 

 

 

INTERPRETATION OF RESULTS

 

POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).

 

*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.

 

NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

PERFORMANCE CHARACTERS:

 

Clinical Sensitivity, Specificity and Accuracy

 

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) has correctly identified specimens of a seroconversion panel and has been compared to a leading commercial TPHA Syphilis test using clinical specimens. The results show that the relative sensitivity of The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) is 99.5% and the relative specificity is 99.3%.

 

Syphilis Rapid Test Device vs. TPHA

 

MethodTPHATotal Results
Syphilis Rapid Test DeviceResultsPositiveNegative
Positive3944398
Negative2540542
Total Results396544

940

 

 

Relative sensitivity: 99.5% (98.2%-99.9%)*

 

Relative specificity: 99.3% (98.1%-99.8%)*

 

Accuracy: 99.4% (98.6%-99.8%)* * 95% Confidence Intervals

Precision

 

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for the control line failure. Review the procedure and repeat the test with a new device. If problem persists, please contact your local distributor.

 

 
ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry
Product Tags: infection blood test   bacterial infection blood test  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Orient New Life Medical Co.,Ltd.
Subject:
Message:
Characters Remaining: (80/3000)