China Shell And Tube Heat Exchanger manufacturer
Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Wuhan Qiaoxin Refrigeration Equipment Co., Ltd. Shell and Tube Heat Exchanger Expert
9
Home > Products > Shell And Tube Heat Exchanger >

Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling

Browse Categories

Wuhan Qiaoxin Refrigeration Equipment CO., LTD

City: wuhan

Province/State:hubei

Country/Region:china

Tel:86-155-2701-1936

Contact Person:
Mrs.Nichole Deng
View Contact Details

Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling

Brand Name GREEFOUN
Model Number QXU110S8
Certification CE
Place of Origin CHINA
Minimum Order Quantity 1piece
Payment Terms T/T, L/C, Western Union
Supply Ability 100000pieces/year
Delivery Time within 15days
Packaging Details Standard export package
Refrigerant R22
Shell material Carbon steel
System Double system
Cooling capacity 18KW~4000KW
Type Shell and tube type
Refrigerating medium Water
Detailed Product Description

Water to Water Tube Heat Exchanger

 

Water - Cooled Evaporator

 

Condenser and evaporator in the structure can be exactly the same, to see where the use of the.

 

Generally in the unit cooling, the refrigerant evaporates inside, that is, evaporator, refrigerant

 

condensation in the inside, called the condenser.

 

In the case of the same heat transfer medium, the condenser of a single chiller is generally larger than the

 

evaporator and the heat transfer area ratio is about 5.5: 4.5.

 

Because the condenser but also a scattered energy into the heat.

 

The two are roughly speaking, there is no difference, are the heat exchanger, but the use of different

 

purposes, the condenser used to discharge heat, the evaporator used to absorb heat.

 

Carefully speaking, there are differences:

 

In the condenser design, should be sub-channel, different road entrance should be as close as possible,

 

exports should also be as close as possible, imports and exports should also be as far as possible to

 

avoid due to heat loss and loss of part of the heat transfer to avoid uneven distribution of traffic The In the

 

actual design, if the split more than two, should be used centralized dispenser and collectors, as far as

 

possible between the different flow of uniform flow. The piping of the different flow paths is preferably the

 

same, and should flow evenly across the windward side and the leeward side so that the heat transfer is

 

uniform.

 

For the evaporator, the requirements are similar, relatively speaking, can be simple, the most common is

 

the liquid into the liquid part of the split head, divided into more road, and the liquid head must be installed

 

vertically. The condenser is not split head, the use of sub-gas header.

 

STEAM TO WATER HEAT EXCHANGER

 

CAPACITY: 1000KW TO 4000KW

 

ModelCapacity (KW)Dimension (mm)Weight (kg)
DT1TACEFH1H2
QXSW60S10100027316002053120360150100350240297
QXSW70S12125032520322498150406180120350240357
QXSW80S12140032520322498150406180120350240372
QXSW90S12160032520322498150406180120350240387
QXSW100S12180032520322498150406180120350240412
QXSW120S14210035520322555150440180120400290494
QXSW140S14250035525003023180440180120400290517
QXSW180S16320042625002951180530260150260260729
QXSW220S16400042625002951180530260150260260784

 

ModelS1S2W
SpecificationConnection typeSpecificationConnection typeSpecificationConnection type
QXSW60S10DN100male flangeDN65male flangeDN80male flange
QXSW70S12DN100male flangeDN65male flangeDN80male flange
QXSW80S12DN125male flangeDN80male flangeDN100male flange
QXSW90S12DN125male flangeDN80male flangeDN100male flange
QXSW100S12DN125male flangeDN80male flangeDN100male flange
QXSW120S14DN125male flangeDN80male flangeDN100male flange
QXSW140S14DN125male flangeDN80male flangeDN100male flange
QXSW180S16DN150male flangeDN100male flangeDN125male flange
QXSW220S16DN150male flangeDN100male flangeDN125male flange

 

 

 

CONDENSER SERIES SINGLE CIRCUIT

 

CAPACITY: 75RT TO 100RT

 

ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACEH1H2
QXC75S12A7528.3503252032248512036018035024033557.2
QXC80S12A8030.2403252032248512040618035024034361
QXC85S12A8532.1303252032248512040618035024035064.1
QXC90S12A9034.0203252032248512040618035024036468
QXC95S12A9535.9103252032248512040618035024037272.1
QXC100S12A10037.8003252500296612040618035024037976

 

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)W (optional port)
FPT(inner pipe thread)Male flangeMale flange
QXC75S12A3/82-1/81-3/8DN80DN100
QXC80S12A3/82-1/81-3/8DN80DN100
QXC85S12A3/82-5/81-3/8DN100DN100
QXC90S12A3/82-5/81-3/8DN100DN100
QXC95S12A3/82-5/81-3/8DN100DN100
QXC100S12A3/83-1/81-5/8DN100DN100

 

WATER TO WATER HEAT EXCHANGER

 

CAPACITY: 100KW TO 400KW

 

ModelCapacity (KW)Dimension (mm)Weight (kg)
DT1TACEFG
QXWW8S6100168762858801859280051
QXWW15S620016812701366801859280078
QXWW20S8300219127013801002381138030/0118
QXWW30S8400219127013801002381138030/0131

 

ModelW1W2
SpecificationConnection typeSpecificationConnection type
QXWW8S6G1-1/2internal pipe threadG1-1/2internal pipe thread
QXWW15S6G1-1/2internal pipe threadG1-1/2internal pipe thread
QXWW20S8G2internal pipe threadG2internal pipe thread
QXWW30S8G2-1/2internal pipe threadG2-1/2internal pipe thread

 


 

COOPERATED CLENTS
 

Product Tags: tube and shell heat exchanger   u tube heat exchanger  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Subject:
Message:
Characters Remaining: (80/3000)