Panasonic 3000r/m MSM Minas 200HZ AC Servo Motor 116V 43A MDMA302S1C
|
Panasonic 3000r/m MSM Minas 200HZ AC Servo Motor 116V 43A MDMA302S1C
Specifications: Control input (1) servo-ON input Control output (1) Servo-alarm output Position control Control input (1) Deviation counter clear input Control output (1) In-position output Pulse Max. command pulse frequency 500 kpps (Optocoupler interface), 8 Mpps (When using line receiver input multiplied by 4) Input pulse signal format Differential input. Selectable by parameter. Electronic gear Applicable scaling ratio: 1/1000 times to 8000 times Smoothing filter Primary delay filter or FIR type filter is adaptable to the command input Analog Torque limit command input Individual torque limit for both positive and negative direction is enabled. Torque feed forward input Analog voltage can be used as torque feed forward input. Two-degree-of-freedom control Available Anti-vibration control Available Load variation suppression function Available Speed control Control input (1) Internal command velocity selection input Control output (1) Speed coincidence output Analog Velocity command input Velocity command input with analog voltage is possible. Scale setting and command polarity vary depending on parameters. (6 V/Rated rotational speed: Default) Torque limit command input Individual torque limit for both positive and negative direction is enabled. Torque feed forward input Analog voltage can be used as torque feed forward input. Internal velocity command Switching the internal 8 speed is enabled by command input. Soft-start/down function Individual setup of acceleration and deceleration is enabled, with 0 s to 10 s/ 1000 r/min. Sigmoid acceleration/deceleration is also enabled. Speed zero clamp Internal velocity command can be clamped to 0 with speed zero clamp input. Two-degree-of-freedom control Available Torque control Control input Speed zero clamp input, torque command sign input, control mode switch input. Control output (1) Speed coincidence output Analog Torque command input Torque command input with analog voltage is possible. Scale setting and command polarity vary depending on parameters. (3 V/rated torque Default) Speed limit function Speed limit value with parameter is enabled. Full-closed control Control input (1) Deviation counter clear input Control output (1) In-position output Pulse Max. command pulse frequency 500 kpps (Optocoupler interface), 8 Mpps (When using line receiver input multiplied by 4) Input pulse signal format Differential input. Selectable by parameter. Electronic gear Applicable scaling ratio: 1/1000 times to 8000 times Smoothing filter Primary delay filter or FIR type filter is adaptable to the command input Analog Torque limit command input Individual torque limit for both positive and negative direction is enabled. Torque feed forward input Analog voltage can be used as torque feed forward input. Setting range of external scale 1/40 times to 1280 times Two-degree-of-freedom control Available Anti-vibration control Available Common Auto tuning The load inertia is identified in real time by the driving state of the motor operating according to the command given by the controlling device and set up support software “PANATERM”. The gain is set automatically in accordance with the rigidity setting. Division of encoder feedback pulse Set up of any value is enabled (encoder pulses count is the max.). Protective function Hard error Over-voltage, under-voltage, over-speed, over-load, over-heat,
over-current and Soft error Excess position deviation, command pulse division error, EEPROM error etc. Alarm data trace back Tracing back of alarm data is available
power 100 V Main circuit Single phase 100 V +10 %-15 % ~120 V +10
%-15 % 50 Hz / 60 Hz Control circuit Single phase 100 V +10 %-15 % ~120 V +10 %-15 % 50
Hz / 60 Hz 200 V Main circuit A-frame to D-frame Single/3-phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz /
60 Hz E-frame, F-frame Single/3-phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz /
60 Hz Control circuit A-frame to D-frame Single phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz / 60
Hz E-frame, F-frame Single phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz / 60
Hz Environment temperature Ambient temperature: 0 ˚C to 55 ˚C (free
from freezing) Storage temperature: –20 ˚C to 65 ˚C (Max.temperature guarantee: 80 ˚C for 72 hours free from
condensation*1) humidity Both operating and storage : 20 % to 85 %RH (free from
condensation*1) Altitude Lower than 1000 m Vibration 5.88 m/s2 or less, 10 Hz to 60 Hz Control method IGBT PWM Sinusoidal wave drive Encoder feedback 23-bit (8388608 resolution) absolute encoder,
7-wire serial * When using the product as an incremental system (not using
multi-turn data), do not connect a battery for absolute encoder.
Instead, set the parameter Pr0.15 to [1] (default). External scale feedback A/B phase, initialization signal
defferential input. Manufacturers that support serial communication scale: Fagor Automation S.Coop., Magnescale Co., Ltd., Mitutoyo
Corporation Nidec Sankyo Corporation, Renishaw plc Parallel I/O connector Control signal Input General purpose 10
inputs The function of general-purpose input is selected by parameters. Output General purpose 6 outputs The function of general-purpose output is selected by parameters. Analog signal Input 3 inputs (16-bit A/D : 1 input, 12-bit A/D : 2
inputs) Output 2 outputs (Analog monitor: 2 output) Pulse signal Input 2 inputs (Photo-coupler input, Line receiver
input) Both open collector and line driver interface can be connected. High speed line driver interface can be connected. Output 4 outputs ( Line driver: 3 output, open collector: 1 output) Line driver output for encoder pulses (A/B/Z signal) or external
feedback pulses (EXA/EXB/EXZ signal) open collector output also
available for Z or EXZ signal. Communication function USB USB interface to connect to computers for parameter
setting or status monitoring. RS232 1:1 communication RS485 1: n communication (max 31) Safety function A dedicated connector is provided for Functional
Safety. Front panel (1) 5 keys (2) LED (6-digit) Regeneration A-frame, B,-frame: no built-in regenerative resistor
(external resistor only) C-frame to F-frame: Built-in regenerative resistor (external
resistor is also enabled.) Dynamic brake A-frame to F-frame: Built-in Control mode Switching among the following 7 mode is enabled, (1) Position control (2) Speed control (3) Toque control (4) Position/Speed control (5) Position/Torque control (6) Speed/Torque control (7) Full-closed control
OTHER SUPERIOR PRODUCTS Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA- Westinghouse Modules 1C-,5X- Emerson VE-,KJ- Honeywell TC-,TK- Fanuc motor A0- Rosemount transmitter 3051- Yokogawa transmitter EJA- Contact person: Anna E-mail: wisdomlongkeji@163.com Cellphone: +0086-13534205279 |
![]() |
75UMD301CACAA SERVO MOTOR UNIMOTOR UM 3000 RPM 75MM FRAME 6 POLE |
![]() |
NTM-330-CBNS-0000 EMERSON Servo Motor NT 3 Inch 230 VAC 1.49 KW 4000 RPM |
![]() |
C5050200STD PROCCESS CONTROLLER 85-265 VAC 50/60 HZ STANDARD BUILD |
![]() |
MGE-455-CONS-0000 MG SERVO MOTOR 230VAC 3000 RPM MAX SPEED MS CONNECTORS |
![]() |
MGE-316-CBNS-0000 MG SERVO MOTOR 230 VAC 3" FRAME 24 VDC BRAKE |
![]() |
MGE-316-CONS-0000 MG SERVO MOTOR 230VAC 18.6 LB-IN CONT TORQUE |