AB 1746-NO4V , SLC 500 Analog Output Module , 10 VDC
|
Detailed Product Description
AB 1746-NO4V , SLC 500 Analog Output Module , 10 VDCTechnical Specifications for 1746-NO4V
About 1746-NO4VThe AB 1746-NO4V is a Four (4) point, non-isolated SLC 500 standard
analog voltage output module. It has an output range of -10 to 10 Volts -1 LSB DC with backplane current ratings of 55 mA at 5 Volts and 145 mA at 24 Volts. AN external 24 VDC power supply may use with this module by activating SW1 external. If the backplane power is sufficient, the backplane power may be used as the power source of this module instead of an external supply. The 1746-NO4V has a field wiring to backplane isolation of 500 Volts DC, and a maximum load reactance of 1 µF and maximum load current of 10 mA. This module is a factory calibrated module and uses a 16-bit two’s complement binary communication format. The 1746-NO4V is enclosed in an open-type enclosure and mounts on a 1746 chassis. It is also equipped with an LED status indicator and a removable terminal block (RTB). Recommended wire size for this module is #14 AWG maximum wire size. Its update time is 512 µs for all the channels that are in parallel, and it has a step response time of 2.5 ms at 95%. The 1746-NO4V’s operating temperature ranges from 32 to 140 degrees Fahrenheit, its non-operating temperature ranges from -40 to 185 degrees Fahrenheit and its non-condensing relative humidity for operation and storage is 5 to 95%. The 1746-NO4V’s has a maximum overall accuracy drift of +/- 54 ppm/degrees Celsius full scale. The AB 1746-NO4V module is a Programmable Logic Controller (PLC) analog output module that belongs to the SLC 500 product platform. The output channels of this module produce voltage signal ranging from -10 to +10VDC signals. When installing this module to the chassis, certain guides may be used for determining the ideal slot or chassis assignment of the module. Two (2) general factors are considered such as ambient Temperature and Electrical noise. For electrical noise, the module is recommended to be installed away from AC or high levels of DC voltage. Additionally, it is best to install this module away from the system power supply. For ambient temperature consideration, the chassis that is nearest to the enclosure bottom is the recommended installation chassis. This module does not support removal under power. Never remove this module when power is applied as electrical arcs may happen causing damage to the electronic circuitry. The module may also be installed with the Removable Terminal Block (RTB) installed in its front panel. Use 14 AWG wire and limit a maximum of Two (2) wires terminated in the same terminal. This is to provide room for troubleshooting as well as be able to close the module cover. Analog outputs may be assigned to a PID controller output, a result of Mathematical operation or a manual value entered from a Human Machine Interface (HMI), or Supervisory Control and Data Acquisition (SCADA). These are control commands sources. It may also be used to re-transmit signals for reference of other devices to implement their monitoring, recording and conversion applications. For stand alone controllers that require control coordination such as load sharing function, analog outputs may be used to send the reference signal of all involved controllers and devices.
|
||||||||||||||||||||||||||||||||||||||||||
Product Tags: 240VAC Isolated Relay Output Module PLCs Solid State Microcomputer Module ESCPP Positive Logic Output Module |
Related Products
![]() |
ABB INNPM12 NETWORK PROCESSOR MODULE DCS Module +5VDC 10W MAX |
![]() |
KJ3002X1-BA1 INPUT MODULE 8 CHANNEL 4-20 MA HART BUS POWER 12 V |
![]() |
DI801 3BSE020508R1 INPUT MODULE DIGITAL 24 VDC 16 CHANNEL PLC Module |
![]() |
ABB NTCL01 INFI-Net Communication Link TU Module Termination Unit |
![]() |
Honeywell 51400955-100 Processor Control Board Multi Input Output Network Interface Board |
![]() |
Honeywell CC-PAIX01 Analog Input Module 51405038-275 100MA 24VDC |