GE general module IC693ADS301 ac contactor IC693ACC300 IC693ALG220
IC693ADS301
Widely used in CNC mechanical metallurgy, petroleum, and natural
gas, petrochemical, chemical, paper printing, textile printing and
dyeing, machinery, electronic manufacturing, automobile
manufacturing, tobacco, plastic machinery, electric power, water
conservancy, water treatment/environmental protection...
Product Description
1. Problems in the operation of ac contactor
Ac contactor is a kind of widely used control electric appliance,
such as the operation of electrical equipment is mainly used to
control motor and stop, ordinary ac contactor in closing, the ac
contactor coil still connected in an alternating current, power
consumption is large, so the coil heat, noise is common, not only a
waste of electricity and the insulation of wire coil easily aging
shortening the service life of ac contactor.
No external power supply is required for this module. The
excitation current for the RTDs is provided by the module, which
automatically matches the excitation current to each configured RTD
type. The module accepts inputs from four independent 3-wire and/or
4-wire platinum, nickel, nickel/iron, or copper RTDs. Module
features include
Function and effect of an energy-saving module of ac contactor
After the energy-saving module is used on the ordinary ac
contactor, the power consumption of ac contactor in the suction
state will be greatly reduced, and the coil temperature will also
be greatly reduced, which can prevent the insulation layer of the
contactor coil from aging due to high temperature, thus extending
the service life of the contactor. Under the suction condition of
ac contactor, the noise is greatly reduced to improve the
environmental conditions of the place where the contactor is used.
Normally only in the ordinary ac contactor coil voltage rating of
85% ~ 110% within the scope of work, when on both ends of the coil
voltage higher than the 110% of the rated voltage, ac contactor
coil may be burned because of fever, after adding the module in the
contactor, contactor's ability to withstand voltage fluctuation, in
the case of the operating supply voltage is too high, ac contactor
coil will not burn for heat.
After the module is added, the sound of the contactor's suction is
clear and powerful. The current in the suction state is only 10% ~
40% of that in the absence of the module, and the power saving rate
is 90% ~ 60%. And after the contactor and reduce noise, keep the
contact for A long time and, the rise of temperature of the
contactor coil surface have no obvious, and even A cool feeling, of
A contactor CJ20-400 test, without energy-saving module (coil
voltage 220 v) contactor after and reach A steady-state voltage is
220 v, current 0.615 A, 52.5 dB noise, the temperature is 105.2 ℃,
after installing modules, reaches A steady-state voltage is 220 v,
current 0.184 A, 36.6 dB noise, the temperature of 26.8 ℃, the
apparent power of the power saving rate is 70%. It can be seen from
the above tests that the current, noise and temperature rise of the
contactor drop significantly after QCJ ac contactor energy-saving
module is installed in the coil loop of the contactor, which proves
that the module can reduce coil loop current, noise and temperature
rise of the contactor.
LED Indicator
The OK LED indicates module status: ▪ On green indicates normal
operation ▪ Flashing green indicates boot mode or update ▪ Flashing
amber indicates self-diagnostic error ▪ Off indicates no 3.3V
backplane power.
Using the Module in Hazardous Locations
▪ WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;
▪ WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN
OFF POWER BEFORE REPLACING OR WIRING MODULES.
▪ WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS
POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE
NONHAZARDOUS.
▪ Equipment labeled with reference to Class I, Div. 2, Groups A, B,
C and D, Hazardous Locations is suitable for use in Class I, Div.
2, Groups A, B, C, D or non-hazardous locations only.
▪ Equipment labeled with reference to Class I, Zone 2, Groups A, B,
C and D, hazardous locations is suitable for use in Class I, Zone
2, Groups A, B, C, D or non-hazardous locations only.
▪ Be sure to read the installation instructions provided with the
module and its terminal assembly. These instructions specify the
use of copper conductors and wire gauge and type requirements.
Similar models:
IC693ACC300
IC693ADS301
IC693ALG220
IC693ALG221
IC693ALG222
IC693ALG223
IC693ALG390
IC693ALG391
IC693ALG392
IC693ALG442
IC693APU300
IC693APU305
IC693BEm331
IC693CHS391
IC693CHS392
IC693CHS393
IC693CHS397
IC693CHS398
IC693CHS399
IC693CMM301
IC693CMM302
IC693CMM311
IC693CMM321
IC693CPU311
IC693CPU313
IC693CPU323
IC693CPU331
IC693CPU340
IC693CPU341
IC693CPU350
IC693CPU351
IC693CPU352
IC693CPU360
IC693CPU363
IC693CPU364
IC693CPU374
IC693MAR590
IC693MDL230
IC693MDL231
IC693MDL240
IC693MDL241
IC693MDL310
IC693MDL330
IC693MDL340
IC693MDL390
IC693MDL632
IC693MDL634
IC693MDL645
IC693MDL646
IC693MDL648
IC693MDL653
IC693MDL654
IC693MDL655
IC693MDL730
IC693MDL731
IC693MDL732
IC693MDL733
IC693MDL734
IC693MDL740
IC693MDL741
IC693MDL742
IC693MDL748
IC693MDL750
IC693MDL751
IC693MDL752
IC693MDL753
IC693MDL930
IC693MDL931
IC693MDL940
IC693MDR390
IC693PBM200
IC693PBM201
IC693PCM300
IC693PCM301
IC693PCM311
IC693PRG300
IC693PWR321
IC693PWR322
IC693PWR328
IC693PWR330
IC693PWR331
IC693PWR332
IC693APU301
IC693APU302
IC693DSM302
IC693DSM314
IC697ALG230
IC697ALG320
IC697ALG440
IC697ALG441
IC697BEM711
IC697BEM713
IC697BEM731
IC697BEM733
IC697BEM741
IC697BEM761
IC697CGR772
IC697CGR935
IC697CHS750
IC697CHS782
IC697CHS783
IC697CHS790
IC697CHS791
IC697CMM711
IC697CMM721
IC697CMM741
IC697CMM742
IC697CPM790
IC697CPM914
IC697CPM915
IC697CPM924
IC697CPU731
IC697CPU732
IC697CPU771
IC697CPU772
IC697CPU781
IC697CPU782
IC697CPX772
IC697CPX782
IC697CPX928
IC697CPX935
IC697HSC700
IC697MDL240
IC697MDL241
IC697MDL250
IC697MDL251
IC697MDL252
IC697MDL253
IC697MDL254
IC697MDL340
IC697MDL341
IC697MDL350
IC697MDL640
IC697MDL651
IC697MDL652
IC697MDL653
IC697MDL654
IC697MDL740
IC697MDL750
IC697MDL752
IC697MDL753
IC697MDL940
IC697MEM713
IC697MEM715
IC697MEM717
IC697MEM719
IC697MEM731
IC697MEM732
IC697MEM733
IC697MEM735
IC697MEM711
IC697PWR710
IC697PWR711
IC697PWR724
IC697PWR748
IC697RCM711
Company profile:
Shipping:
FAQ
* Q: Do you provide a warranty for the goods?
A: Yes, we provide a warranty for all the goods from us.
* Q: Could Wisdomlong provide technology support?
A: We're in this field for more than 8 years. If there's any
problem, please contact us, we'll provide a suggestion from our
engineer to help you solve the problem.
* Q: Does Wisdomlong keep goods in stock or only trading?
A: We have a large warehouse for goods. Keep lots of goods in the
warehouse, so could promise a fast delivery.
* Q: What is your MOQ?
A: We provide you small MOQ for each item, it depends on your
specific order!
* Q: Do you test all your goods before delivery?
A: Yes, we have a 100% test before delivery.
* Q: How do you make our business long-term and good relationship?
A: We keep good quality and competitive price to ensure our
customers benefit ;
We respect every customer as our friend and we sincerely do
business and make friends with them, no matter where they come
from.
Send your Inquiry Details in the Below, Scan "me" Now!