Bently Nevada 3500/22M Transient Data Interface TDI Operation 146031-01
|
Bently Nevada 3500/22M Transient Data Interface TDI Operation 146031-01
Features
TDI operates in the RIM slot of a 3500 rack in conjunction with the M series monitors (3500/40M, 3500/42M, etc.) to continuously collect steady state and transient waveform data and pass this data through an Ethernet link to the host software. Static data capture is standard with the TDI, however using an optional Channel Enabling Disk will allow dynamic or transient data to be captured as well. TDI has made improvements in several areas over previous communication processors in addition to incorporating the Communication Processor function within the 3500 rack.
TDI provides certain functions common to the entire rack, however the TDI is not part of the critical monitoring path and has no effect on the proper, normal operation of the overall monitor system. One TDI or RIM is required per rack. The TDI occupies only a single slot in the rack and is always located in Slo t 1 (next to the power supplies).
For Triple Modular Redundant (TMR) applications, the 3500 System requires a TMR version of the TDI. In addition to all the standard TDI functions, the TMR TDI also performs "monitor channel comparison". The 3500 TMR configuration executes monitoring voting using the setup specified in the monitor options. Using this method, the TMR TDI continually compares the outputs from three (3) redundant monitors. If the TMR detects that the information from one of those monitors is no longer equivalent (within a configured percent) to the remaining two, it will flag the monitor as being in error and place an event in the System Event List.
Estimated Shipping Size
Similar Products: BENTLY NEVADA 3300/20-XX-03-01-00-00 BENTLY NEVADA 3300/26-XX-XX-XX-00-00-01-00 BENTLY NEVADA 3300/35-02-02-01-00-00 BENTLY NEVADA 3300/40-03-01-02-00-00 BENTLY NEVADA 3300/40-13-01-01-00-00 BENTLY NEVADA 3300/46-XX-XX-01-00 BENTLY NEVADA 3300/47-XX-XX-02-00 BENTLY NEVADA 3300/48-01-01-00-00 BENTLY NEVADA 3300/48-03-02-00-00 BENTLY NEVADA 3300/48-03-02-02-00 BENTLY NEVADA 3300/48-04-02-01-00 BENTLY NEVADA 3300/50-02-01-00-00 BENTLY NEVADA 3300/50-02-02-00-00 BENTLY NEVADA 3300/55-01-04-02-02-00-00-04-00 BENTLY NEVADA 3300/55-01-04-12-12-00-00-05-00 BENTLY NEVADA 3300/55-01-05-02-02-00-00-09-00 BENTLY NEVADA 3300/55-01-05-12-12-00-00-05-00 BENTLY NEVADA 3300/61-03-01-01-00-00-00 BENTLY NEVADA 3300XL extension cable1 BENTLY NEVADA 330130-045-00-00 BENTLY NEVADA 330930-045-00-05 BENTLY NEVADA 330930-065-00-05 BENTLY NEVADA 330930-065-03-05 The 3500 Transient Data Interface (TDI) is the interface between
the 3500monitoring system and GE’s System 1* machinery management
software. TheTDI combines the capability of a 3500/20 Rack
Interface Module (RIM) with thedata collection capability of a
communication processor such as TDXnet. The TDI operates in the RIM slot of a 3500 rack in conjunction wittheMseriesmonitors(3500/40M,3500/42M, etc.) to continuously collect steady state andtransient waveform data and pass this data through an Ethernet link to the hostsoftware. (Refer to the Compatibility section atthe end of this document.) Staticdata capture is standard with the TDI, however using an optional ChannelEnabling Disk will allow the TDI to capture dynamic or transient data as well. TheTDI features improvements in several areas over previous
communicationprocessors and incorporates theCommunication Processor
function within the3500 rack. Although the TDI provides certain functions common to the entire rack it is notpart of the critical monitoring path and has no effect on the proper, normaloperation of the overall monitor system. Every 3500 rack requires one TDI orRIM, which always occupies Slot 1 (next to the power supplies). For Triple Modular Redundant (TMR) applications, the 3500 System requires aTMR version of the TDI. In addition to all the standard TDI functions, the TMR TDIalso performs “monitor channel comparison”. The 3500 TMR configurationexecutes monitor voting using the setup specified in the monitor options. Usingthis method, the TMR TDI continually compares the outputs from three (3)redundant monitors. If the TDI detects that the information from one of thosemonitors is no longer equivalent (within a configured percent) to that of the othertwo monitors, it will flag the monitor as being in error and place an event in the System Event List. Contact person: Anna E-mail: wisdomlongkeji@163.com Cellphone: +0086-13534205279
|
||||||||
Product Tags: plc circuit board servo motor controller board |
![]() |
HLA3400T 2602D98G32 CUTLER HAMMER CIRCUT BREAKER TRIP UNIT LA 400AMP FR TRIP UNIT 3POLE |
![]() |
01984-1045-0003 EMERSON Processor Board Peerway I/O Interface Card PLC |
![]() |
EMERSON 01984-3202-0010 INPUT/OUTPUT PROCESSOR MODULE LED SIGNALS |
![]() |
01984-1144-0001 EMERSON DC POWER DISTRIBUTION BUS RS3 Control Circuit Board |
![]() |
3HAC3619-1 ABB AXIS PC COMPUTER BOARD ROBOTICS DSQC 503 Spare Parts |
![]() |
HNC31200F WESTINGHOUSE CIRCUIT BREAKER 1200 AMP 3 POLE 600 VAC |