Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200
|
Redundant Power Supply Module SCHNEIDER TSX QUANTUM MODICON
140NPR31200 Item 140 NRP 312 00 140 NRP 312 01
Optical Transmitter Specifications optical power –23.5...–14 dBm with 50/125 µm fibercable
Mechanical Specifications weight 1 kg (2 lb) max
Operating Conditions RFI immunity (IEC 1000-4-3) 80...1000 MHz, 10 V/m
Operating Conditions temperature 0...60 ° C (32...140 °F)
OTHER SUPERIOR PRODUCTS
Contact person: Anna E-mail: wisdomlongkeji@163.com Cellphone: +0086-13534205279 Similar Products 140ERT85410 140ESI06210 140HLI34000 140MSB10100 140AVI03000 140AVO02000 140CFA04000 140CFB03200
Warning UNINTENDED EQUIPMENT OPERATION Do not connect a 140 NRP 312 01 single-mode fiber converter module to a 140 NRP 312 00 multi-mode fiber converter module. Failure to follow these instructions can result in death, serious injury, or equipment damage.
140 NRP 312 00/01 fiber converter modules are an alternative method
to using a dual-ring switch
Introduction 140 NRP 312 00/01 fiber converter modules have 2 copper ports and 2 fiber ports. The fiber ports, in both multi-mode and single-mode modules, use LC-type connectors. One fiber port is used as the transmitter signal (Tx), and the other fiber port is used as the receiver signal (Rx). There are 2 models of fiber converter modules, each supporting one type of fiber cable: 140 NRP 312 00 supports multi-mode fiber cable. 140 NRP 312 01 supports single-mode fiber cable.
140 NRP 312 00/01 Description The following figure shows the 140 NRP 312 00/01 fiber converter module:
1 model number, description code, color code 2 LEDs 3 removable door 4 customer identification label (Fold label and place it inside door.) 5 Ethernet port 1 6 Ethernet port 2 7 fiber port 1
Installing Fiber Converter Modules to Extend Distance Between the Local Rack and an RIO Drop The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m.
1 140 NRP 312 00/01 fiber converter module interlinked with the 140
CRP 312 00 RIO head module on the local rack
Installing Fiber Converter Modules to Extend Distance Between RIO Drops The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m.
1 140 NRP 312 00/01 fiber converter module interlinked with the 140
CRP 312 00 RIO head module on thelocal rack
Installing Fiber Converter Modules to Extend Distance Between DIO Devices The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between DIO devices beyond 100 m.
1 Quantum CPU on the primary local rack
Installing Fiber Converter Modules in a Hot Standby System The following figure shows a Quantum EIO Hot Standby network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m. The use of fiber converter modules are useful to help avoid noise, attenuation, and/or distant grounding when the distance between the primary and standby PLCs exceeds 100 m.
1 Quantum CPU on the primary local rack
|
||||||||
Product Tags: plc power supply module diode redundancy module |
![]() |
3BSE000863R0001 SR511 POWER REGULATOR MODULE 310 W MAX 35 AMP 18-30 VDC INPUT 5 VDC OUTPUT |
![]() |
Honeywell TK-FXX102 Redundant Power Supply Module 10SLOT Coated 5.1VDC - 24VDC |
![]() |
Honeywell TC-ODJ161 Output Module Isolated Discrete 16 Point 24 VDC |
![]() |
EMERSON FISHER ROSEMOUNT 01984-1137-0001 POWER SUPPLY I/O PCB BOARD MODULE |
![]() |
AO801 Analog Input Output Module 3BSE020514R1 ABB 20mA 12 Bit RLmax 850 Ohm |
![]() |
ABB AC 800F TK808F Supply Cable 3BDM000211R1 115/230 VAC Euro Plug 2 M |