Electronic Interface Module IC695PBM300 RX3i Profibus DP Master Module
|
Redundant Power Supply ModuleGE Fanuc IC695PBM300 RX3i Profibus DP
Master module
Upgrade Kit: 44A753033-G02 Supports all standard data rates
Similar Products IC660EBD020 Electronic Assembly for IC660BBD020 IC660EBD021 Electronic Assembly for IC660BBD021 IC660EBD024 Electronic Assembly for IC660BBD024 IC660EBD025 Electronic Assembly for IC660BBD025 IC660EBD101 Electronic Assembly for IC660BBD101 IC660EBD110 Electronic Assembly for IC660BBD110 IC660EBR100 Electronic Assembly for IC660BBR100 IC660EBR101 Electronic Assembly for IC660BBR101 IC660EBS102 Electronic Assembly for IC660BBS102 IC660EBS103 Electronic Assembly for IC660BBS103 IC660EBA021 Electronic Assembly for IC660BBA021 IC660EBA023 Electronic Assembly for IC660BBA023 IC660EBA101 Electronic Assembly for IC660BBA101 IC660EBA103 Electronic Assembly for IC660BBA103 IC660EBD120 Electronic Assembly for IC660BBD120 IC660HHM501 Hand-Held Monitor includes Cable and Battery Charger IC660ELB906 PCIM (XT/AT Interface Board) & S/W Driver (IC641GBE647) IC660ELB921 Single-slot PCIM (XT/AT Interface Board) 1-channel Release Information Version 1.04 of the IC695PBM300 RX3i PROFIBUS Master resolves the
following issues:
Upgrade Kit: 44A753033-G02 Module Status Information For details on using the Communication Request function to
communicate with the PROFIBUS master module, refer tothe PACSystems
RX3i PROFIBUS Modules User’s Manual, GFK-2301. Slave Status Bit Array The Slave Status bit array contains a bit for each slave. If communication with a slave has no errors, the bitcorresponding to the slave (determined by its network address) is set. If the communication has errors or is not occurring for any reason, the bit is cleared. The Master also maintains its own status in the bit corresponding to its network address. Slave Diagnostics ID Array If diagnostics are pending, the first word of this two-word array contains the station address of the first slave that has diagnostics. The diagnostics can be read using the Get Device Diagnostics COMMREQ (command 4). This clears the word and the master then places the next pending diagnostic address into the Slave Diagnostics word. If this word is zero there are no pending diagnostics.The second word of this array is reserved and set to 0. DPV1 Alarm Status Array The 32-bit DPV1 Alarm Status array is used at the beginning of a
scan to receive the station address of a slave that has sent a DPV1
Alarm message. If another slave has sent a DPV1 alarm message, it
is ignored until the first one has been serviced, and will then appear in a subsequent scan. For details on the status format, refer to “DPV1 Alarm AcknowledgeCOMMREQ” in GFK-2301. Slave Configured Bits This 128-bit array indicates which slaves on the PROFIBUS network are configured. Each slave has a corresponding bit in this array. A slave's configuration status address equals Start Address + Station Address of the slave. For example, if the configuration status bits are mapped to %I00001, the status for the slave at Station Address 5 would be found at %I00001 + 5=%I00006. Slave Diagnostic Bits This 128-bit array indicates which slaves on the PROFIBUS network have diagnostic data available. The diagnostics can be read using the Get Device Diagnostics COMMREQ (command 4). Each slave has a corresponding bit in this array. A slave's diagnostic status address equals Start Address + Station Address of the slave. For example, if the configuration status bits are mapped to %I00001, the status for the slave at Station Address 5 would be found at %I00001 + 5=%I00006. Connecting the Module to the PROFIBUS Network The module contains a standard female DB9 connector, labeled
“PROFIBUS,” that can be connected to a PROFIBUS busterminal that
complies with EN 50170. The PROFIBUS module has no built-in termination. If termination is required, you must use a bus terminal that has builtin selectable termination OTHER SUPERIOR PRODUCTS
|
||||||||
Product Tags: plc power supply module diode redundancy module |
![]() |
3BSE000863R0001 SR511 POWER REGULATOR MODULE 310 W MAX 35 AMP 18-30 VDC INPUT 5 VDC OUTPUT |
![]() |
Honeywell TK-FXX102 Redundant Power Supply Module 10SLOT Coated 5.1VDC - 24VDC |
![]() |
Honeywell TC-ODJ161 Output Module Isolated Discrete 16 Point 24 VDC |
![]() |
EMERSON FISHER ROSEMOUNT 01984-1137-0001 POWER SUPPLY I/O PCB BOARD MODULE |
![]() |
AO801 Analog Input Output Module 3BSE020514R1 ABB 20mA 12 Bit RLmax 850 Ohm |
![]() |
ABB AC 800F TK808F Supply Cable 3BDM000211R1 115/230 VAC Euro Plug 2 M |