Benchtop Grating Spectrophotometer TS8500SIntroduction: TS8500S is a benchtop grating spectrophotometer which is developed
by 3nh independently with core technology. It uses a dual-array
CMOS image sensor to have high sensitivity and a wider spectral
response range, which makes the test more accurate. It needs to use
with SQCX color quality management software in PC, which is
convenient and easy operation. The repeatability of ΔE*ab is within
0.015, and Inter-instrument Error is within 0.15, and measurement
performance is super stable and accurate. Features: 1. International common d/8, SCI/SCE , SCI+SCE Synchronous measurement TS8500S spectrophotometer adopts D/8(diffused illumination,
8-degree viewing angle) which is widely applicable in the world,
and SCI/SCE (specular component included/specular component
excluded) Synthesis technology, supporting SCI+SCE simultaneous
rapid measurement. 2. Double Array CMOS Image Sensor; It has high sensitivity and wide spectral response range, which can
achieve high -precision and repeatability measurement. 3. Rich measurement index, multiple observation light sources Support 40+measurement index, D65, A, C, D50, D55, D75, F1, F2, F3,
F4, F5, F6, F7,
F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30B,U35,NBF,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5,and
other customized light sources.(41 light sources in total, parts
will be achieve via software in PC),multiple observation light
sources, meet different measuring requirement. 4. Automatic measuring aperture distinguish Freely switchable between 4 measuring apertures:
φ25.4mm/15mm/8mm/4mm. Users also can customize apertures. 5. Convenient measurement, widely application Side measurement, upward measurement, and downward measurement
(using accessories) and other gestures are placed and measured,
open -type transmitted warehouses, adapting to more samples. 6. Automatic temperature and humidity compensation function, make the
measurement data more accurate 7. Adopt combination full spectrum LED light source and UV light
source Wavelength range 360nm-780nm,combined LED Light. Including UV,
400nm cut-off light source, 420nm Cut-off light source, 460nm
Cut-off light source 8. Color management software With SQCX quality management software, TS8500S spectrophotometer is
suitable for quality monitoring and color data management in
various industries. Data the user's color management, compare color
differences, generate test reports, provide multiple color space
measurement data, and customize the customer's color management. TS8500S Benchtop Grating Spectrophotometer Specification: Model | TS8500S (LED, no display pad) | Optical Geometry | Reflect: D/8 (diffused illumination, 8-degree viewing angle) ; | SCI/SCE; Include UV / excluded UV light source ; | Transmittance: D/0 (diffuse illumination: 0° viewing) ; | SCI /SCE; Include UV / excluded UV light source ; | HAZE (ASTM D1003); | Standards meet: CIE No.15,GB/T 3978,GB 2893,GB/T
18833,ISO7724/1,ASTM E1164,DIN5033 Teil7,JIS Z8722 under condition
C | Characteristic | 1. Widely applied in paints, inks, textiles, garments, printing and
dyeing, printing etc industries for color transfer and quality
control. | 2. Instrument can be measured on the side, upward measurement, and
the downward measurement (use accessories) and other gestures. | 3. Open transmission warehouse, available thickness of 54mm
transmitted samples. | 4. Automatic temperature and humidity compensation function. | Integrating Sphere Size | Φ154mm | Light Source Device | 360nm–780nm Wavelength range ,combined LED Light. Including UV,
400nm cut-off light source, 420nm Cut-off light source,460nm
cut-off light source | Spectrophotometric Mode | Concave Grating | Sensor | 256 Image Element Double Array CMOS Image Sensor | Wavelength Range | 360~780nm | Wavelength Interval | 10nm | Semiband Width | 5nm | Measured Reflectance Range | 0~200% | Reflectivity Resolution | 0.01 | Measuring Aperture | Reflective: | XLAV Φ25.4mm/Φ30mm, LAVΦ15mm/Φ18mm , MAVΦ8mm/Φ10mm, SAVΦ4mm/Φ6mm | Transmissive: | Φ25.4mm(No limit on sample height and width, but thickness≤54mm) | Remark: | 1. Automatic identification of aperture switch | 2. Customized Configuration caliber and lens position | Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE | Color Space | CIE LAB,XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN
Lab99 | Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,
DINΔE99,ΔE(Hunter),ΔE*CH,555 Index | Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter,Taube,Berger Stensby) | YI(ASTM D1925,ASTM 313),ISO brightness,R457 | MI (Metamerism Index), | Staining Fastness, Color Fastness, Color Strength, Opacity, | APHA/Hazen/Pt-Co Index,Gardner Index | 8° Gloss,555 Index, Haze,Transmission(ASTM D1003),Saybolt index,
ASTM D1500 Color code,carbon(My,dM),Color density
CMYK(A,T,E,M),Tint,Color density(part function achieved via
software in PC) | Observer Angle | 2°/10° | Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF | ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5,
customized light source(41 light sources in total,part achieved via
software in PC) | Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference
Values/Graph, PASS/FAIL Result, Color Offset, Color assessment,
haze, liquid chromaticity | Measuring Time | 2.0s (Measure SCI & SCE meantime about 4s ) | Repeatability | Reflectance chromaticity value:Φ25.4mm/SCI, Standard deviation
within ΔE*ab 0.015 ( Under LED light source, when a white
calibration plate is measured 30 times at 5 second intervals after
white calibration); | spectrum reflectance /transmission:≤0.1% | Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) | Dimension | L*W*H=440x248x283mm | Weight | Approx. 13.5kg | Power | AC 24V, 3A Power adapter power supply | Illuminant Life Span | 5 years, more than 3 million times measurements | Display | No | Data Port | USB & Bluetooth 5.0 | Data Storage | Share with PC storage | Language | / | Operating Environment | 0~40℃(32~104°F) | Storage Environment | -20~50℃(-4~122°F) | Standard Accessory | Power Adapter, User Guide, U Disk(PC Software), USB cable, Standard
Calibration Board, Black Calibration Cavity, Transmission black
baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4
caliber,Transmissive Test Component, cuvette | Optional Accessory | Micro Aperture(4mm) transmission test clamp component, Instrument
inversion components,culture dish,Film fixture | Notes | Test reports can be printed through a network printer connected to