X-Rite eXact handheld spectrophotometer CMYK delta E lab For Print
& Packaging The X-Rite eXact handheld spectrophotometer takes color measurement
and management to the next level. It is a scalable platform that
can be field upgraded as needs change, from a simple densitometer
to a highly advanced spectral measurement instrument. eXact enables
printers and packaging converters to truly understand, control,
manage, and communicate color through all facets of production ,
avoiding unwanted reprint and rework. Benefits:- Best in Spot Color Support
Fully integrated Pantone spectral data, support of the PantoneLIVE
color digital workflow, and ink key adjustment recommendations for
spot colors and CMYK make eXact best-in-class for handling spot
colors.
- Accurate and Consistent
The combination of the advanced spectral engine and integrated
white calibration ensures the highest accuracy and consistency with
other instruments – all the time. When used with NetProfiler,
customers can ensure accuracy and consistency across multiple
measurement devices within a single facility or across geographies.
- Configurable
eXact allows the user to easily configure and control the
instrument to the specific standards of a selected job.
- Efficient
eXact is built to bring efficiency to your operation with its
ability to do simultaneous polarized and unpolarized measurements
(M0, M2 and M3).
- Expandable
With a comprehensive portfolio of products, the eXact family
integrates with many of X-Rite solutions to ensure color
consistency.
By deploying X-Rite eXact spectrophotometers, print and packaging
operations can significantly reduce makeready times, improve
quality, reduce substrate and ink waste and enjoy a more efficient
workforce. It is the first instrument in the marketplace to combine
unique hardware and software into a single integrated, scalable
solution that helps operations get color right the first time -
every time. SpecificationsShort Term Repeatability - White | 0.05 ΔEab (standard deviation) White BCRA (Error compared to mean
value of 10 measurements every 5 seconds) |
---|
Short Term Repeatability - Density | '+/- 0.01 D for CMYK (Status E or Status T measurements, maximum
error compared to mean value of 10 measurements every 5 seconds at
2.0 D except for M3 Yellow at 1.7 D) |
---|
Measurement Geometry | 45°/0° ring illumination optics, ISO 5-4:2009(E) |
---|
Inter-Instrument Agreement | Average: 0.25 ΔEab, Max: 0.45 ΔEab (for M3: 0.55 ΔEab) (Measurements using X-Rite manufacturing standards at a temperature
of 23°C +/- 1°C, 40-60% RH for all measurement modes on 12 BCRA
color tiles and a white ceramic reference (D50, 2°)) |
---|
Light Source | Gas filled tungsten (illuminant type A) and UV LED |
---|
Measurement Conditions | M0, M1 (part 1) , M2, M3 |
---|
Measurement Time | < 1 sec |
---|
Spectral Analyzer | DRS spectral engine |
---|
Spectral Interval | 10 nm |
---|
Spectral Range | 400 nm to 700 nm |
---|
Spectral Reporting | 400 nm to 700 nm with 10mm interval |
---|
Color Differences | CIE ∆E* (1976), ∆ECMC, CIE ∆E* (2000), and CIE ∆E* (1994) |
---|
Color Spaces | CIE L*a*b*, CIE L*C*h°, CIE XYZ and Yxy |
---|
Illuminants | A, C, D50, D55, D65, D75, F2, F7, F11, D12 |
---|
Observers | 2° and 10° |
---|
Humidity | 30 to 85% RH (non-condensing) |
---|
Operating Temperature Range | 10°C to 35°C 50°F to 95°F |
---|
Storage Temperature Range | -20° to 50°C -4° to 122°F |
---|
Dimensions (length, width, height) | 18 cm x 7.8 cm x 7.6 cm 7.1" x 3.1" x 3.0" |
---|
Weight | 700 g 1.6 lbs. |
---|
3rd Party Software Supported | X-Rite ColorCert, X-Rite Color iQC, X-Rite InkFormulation, X-Rite
NetProfiler and many others |
---|
Communication Interface | USB 2.0 Bluetooth (optional) - Class II |
---|
Configuration Options | Bluetooth, NetProfiler |
---|
Instrument Display | Color touch-screen, 320 x 240 pixels |
---|
Languages Supported | Chinese Simplified, Chinese Traditional, Czech, Danish, Dutch,
English, Finnish, French, German, Hungarian, Italian, Japanese,
Korean, Polish, Portuguese, Russian, Slovenian, Spanish, Swedish,
Turkish |
---|
Software Development Kit | Yes |
---|
Software Modes | Densitometer, Standard, Advanced |
---|
User Experience | Start-up wizard, configurable |
---|
Battery | Lithium Ion, 7.4VDC, 2200mAh |
---|
Voltage | 12 VDC @ 2.5 A |
---|
Sample/Measurement | Max. 5000 samples |
---|
Standards | More than 20'000 standards (incl. data for all M modes) |
---|
Density Range | 0.0 D – 3.0 D |
---|
Density Standards | Status A, E, I, T and G |
---|
Industry Standards | ISO 5-4:2009(E), ISO 13655:2009 |
---|
BestMatch Feature | Yes |
---|
Calibration | Automatic on integrated white reference |
---|
Embedded NetProfiler Support | Yes |
---|
G7 Certification | Yes |
---|
NetProfiler Support | Yes |
---|
PantoneLIVE Support | Yes |
---|
Pass / Fail | Yes |
---|
Warranty | 1 year |
---|
What's Included? | USB cable, power supply, CD with software and documentation,
docking/charging station, quick start guide, carrying case, device
certificate |
---|
Macintosh | MacOS X 10.8, 10.9, 10.10, 10.11 |
---|
Windows | Windows XP (32bit), Windows 7 (32 and 64 bit), Windows 8 (32 and 64
bit), Windows 10 (32 and 64 bit) |
---|
|