YUYANG ISO 9239-1 & ASTM E648 Flooring Radiant Panel Test Apparatus
|
|
YUYANG ISO 9239-1 & ASTM E648 Flooring Radiant Panel Test Apparatus
ISO 9239-1: Reaction to Fire Tests for Flooring- Part 1: Determination of Burning Behavior Using a Radiant Source ISO 9239-2: Reaction to Fire Tests for Flooring- Part 2: Determination of Flame Spread at a Hat Flux Level of 25kW/m2 ASTM E 648: Standard Test Method for Critical Radiant Flux of Floor- Covering System Using a Radiant Heat Energy Source Structure: 1. The structure of the machine consists of two parts: a combustion chamber and a control chamber. 2. Combustion chamber size: about L1420*W1200*H2300 (mm). 3. Control chamber/combustion chamber material: high-quality 304 # stainless steel plate, CNC machine processing. 4. Blowtorch: Fully meet the requirements of GB/T 11785. 5. Other mechanical parts are made of 304 stainless steel or 45# steel, anti-corrosion and anti-rust.
1. The resulting test chamber is insulated with calcium silicate insulation board and is provided with a temperature-resistant observation window. 2. The stainless steel sample support assembly is mounted on a sliding platform to allow safe and easy loading of the test sample. 3. The radiant heat is applied by means of a gas-fuelled panel, inclined at 30º, and directed at a horizontally mounted floor covering system specimen. 4. The radiant panel generates a radiant energy flux distribution ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1 kW/m2. 5. Dummy calibration specimen with holder, calibrated heat flux meter, and mounting. 6. The distance burned until flame-out is reached and converted, by calibration, into an equivalent critical radiant flux, in kW/m2. 7. Heat Flux Meter: Range 0 ~ 50 kW/m2; Surface emissivity: ε=0.95± 0.05. 8. A smoke measuring system, according to DIN 50055, is mounted on a separate frame at the exhaust stack. 9. Control Rack for convenience in use, allowing observation of the apparatus and controls during equipment set-up and calibration. 10. It has the function of automatic ignition of the radiant panel and a safety cut-out. Application range: The flooring radiant heat flux test device is for paving materials which are placed horizontally and exposed to a slanted heat radiation field with a small flame; various flooring materials such as: textile rugs, cork boards, wood boards, rubber sheets And plastic floor and floor spray materials. Technical parameters:
|
|
YUYANG ISO 9239-1 & ASTM E648 Flooring Radiant Panel Test Apparatus |
|
ASTM C518 Fire Testing Equipment |
|
Fire Testing Equipment Glow Wire Tester for Textile Testing OEM Customized Vertical High Accuracy IP65 Protection 1 Year |
|
Fire Testing Equipment Solar Cell Spread of Flame & Burning Brand Tester Machine |
|
YY D1929 ISO871 Plastic Ignition Temperature Testing Equipment |
|
IEC 60331, BS 6387, EN 50200 Electric Cables Circuit Integrity Burn Test Apparatus |
