P.I.D. Control Temperature Humidity Test Chamber Incubator With CE
Certification Applications: Temperature and Humidity Test Chamber is also named environmental
test chamber, climatic test chamber, can be applied to test the
properties of heat-resistance, cold-resistance, dry-resistance and
humidity resistance of materials. It is mainly used in testing the
adaptability of electronics, electrical appliances, food,
automobile, rubber and plastic, metal and other products, parts and
materials in the high and low temperature and humid environment
when storage, transport and using. Main technical parameters: Capacity | 80L | 100L | 150L | 225L | 408L | 800L | 1000L | Interior Dimension (W×D×H)MM | 400*400* 500 | 500*400* 500 | 500*500* 600 | 600*500* 750 | 800*600* 850 | 1000*800* 1000 | 1000*1000* 1000 | Exterior Dimension (W×D×H)MM | 1000*870* 1700 | 1050*870* 1750 | 1050*970* 1750 | 1150*970* 1900 | 1350*1150* 1950 | 1450*1300* 2100 | 1470*1400* 2100 | Temperature Range | 0℃~150℃; -20℃~150℃; -40℃~150℃; -60℃~150℃; | Humidity Range | 20%~98%RH | Temperature Volatility | ± 0.5 ℃ | Temperature Uniformity | ±1.5℃ | Humidity Volatility | ±1.0%RH | Humidity Uniformity | ± 2.0% RH | Humidity Area | Notes: Environment temperature:+25℃; R.H.≤85% This two values measured under the condition of no test sample in
the chamber | Heating/Cooling rate | 3℃/min (Room temperature to high temperature 150℃); 1℃/min (room
temperature to minimum temperature). | Control Mode | Balanced temperature & humidity control mode, PID programmable
adjustable. | Communication port | RS232 print interface. | Refrigeration system | Fully enclosed Tecumseh compressor France original, environmentally
friendly refrigerant gas R404A. | Programmable Mode | Has adopted Korean TEMI850 controller English display, 120 program
x 100 step and 100hours/step setting capacity (each step means
specific temperature, humidity and test time), 999 cycles
circulation setting, and enclose multiple sets of PID control
function. | Controller Resolution | 0.01℃, 0.01RH | Exterior Material | SUS#304 stainless steel material | Interior Material | 1.2mm thickness SUS#304 stainless steel, rigid polyurethane
foam+efficient ultra-fine glass cotton insulation materials. | Related Standard | 1. IEC6008-2-1-2007 Electronic Electrician Product Environmental
Test Part 2: test methods --Test Method A: low temperature. 2. IEC68-2-3 Ca test: constant humidity and heat test method. 3. IEC6008-2-30:2005 Db test: humid heat alternation method. | Air Circulation System | Inner air circulation fan, wind channel and stainless steel cycle
fan, through the top window and air diffuser, the wind will out
uniformly from the top, which could reach the purpose of control
temperature uniformly. | Heating System | Adopt heating pipe P.I.D. control the heating so keep temperature
balance. | Humidification& Dehumidification System | Adopt outside water circulation humidification, and compressor is
used for dehumidification, P.I.D. control the volume of
humidification. | Safety Devices | Water level protection, water shutdown protection, over-temperature
protection, high-pressure compressor protection, compressor thermal
protection, compressor overload protection, fast fuse, buzzer
alarm, overload protection. | Door of Chamber | Single open door, anti-explosion, anti-condensation electric
heating device, vacuum auto-defog transparent window, window
internal bulb. | Test Lead Hole | Φ50mm, enclosed with relative temperature preservation and heat
insulation parts. | Power | AC220V±10%, 50/60HZ 3 phase (80L, 100L, 150L); AC380V±10%, 50/60HZ,
3 phase(225L, 408L, 800L, 1000L) | The third Party Certificate | Certified by ISO9001 quality control system and CE requirement |
|