China Flammability Testing Equipment manufacturer
DONGGUAN YUYANG INSTRUMENT CO., LTD
8
Home > Products > Environmental Test Chamber >

Electronic Hot And Cold Temperature Test Chamber , Thermal Shock Test Chamber CE Approved

Electronic Hot And Cold Temperature Test Chamber , Thermal Shock Test Chamber CE Approved

Brand Name YUYANG
Model Number YY1011
Certification CE , UL, ISO
Place of Origin China
Minimum Order Quantity 1 set
Price Negotiation
Payment Terms T/T, L/C, Western Union
Supply Ability 2 sets per month
Delivery Time 15-20 work days
Packaging Details Plywood Case
Product Name temperature testing equipment
Usage Hot and Cold Temperature Thermal Shock
Material stainless steel
High temperature 60 to200’C
Low temperature -78 to 0’C
Power Supply AC220V, 50/60HZ
Setting resolution 1’C
Display LCD (5.7 inches)
Detailed Product Description

Electronic Hot and Cold Temperature Thermal Shock Environmental Test Chamber

 

 

Description:

 

Electronic Hot and Cold Temperature Shock Simulate Test Machine is divided into high temperature area, low temperature area and test area three parts, each area is a unique insulation structure, so doing hot and cold impact test. High-temperature impact test or low-temperature impact test, the maximum time is up to 9999 minutes, the most cycle time is up to 9999 times. The machine can be automatically or manually cycle the impact or selectively set the two areas or three areas to impact of hot and cold. It used binary cooling system that is very effectiveness for cooling, the cooling system is divided into the air-cooled and water-cooled. It also can be connected with a computer, but the record instrument is only for optional purchase. Color LCD touch-control operation interface with Chinese and English, easy to operate.

 

 

Specifications:

 

SystemTwo-zone test by means of damper switching
Three-zone chamber
ModelYY1011-50A/YY1011-50WYY1011-100A/YY1011-100WCustomized
PerformanceTest areaHigh temp. exposure range*1+60~ to +200°C
Low temp. exposure range*1-65to 0 °C
Temp. fluctuation *2±1.8°C
Hot chamberPre-heat upper limit+200°C
Temp. heat up time*3Ambient temp. to +200°C within 30min
Cold chamberPre-cool lower limit-65°C
Temp. pull down time*3Ambient temp. to -65°C within 70min
Temp. recovery (2-zone)Recovery conditionsTwo-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg)
Temp. recovery timeWithin 10 min.
ConstructionExternal materialCold-rolled rust-proofed steel plate
Test area materialSUS304 stainless steel
Door*4Manually operated door with unlock button
HeaterStrip wire heater
Refrigeration unitSystem*5Mechanical cascade refrigeration system
CompressorHermetically sealed scroll compressor
Expansion mechanismElectronic expansion valve
RefrigerantHigh temp side:R404A, Low temp side R23
CoolerStainless steel welded plate heat exchanger
Air circulatorSirocco fan
Damper driving unitAir cylinder
FittingsCable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal
Inside dimensions (W x H x D)350 x 400 x 350500 x 450 x 450Customized
Test area capacity50L100LCustomized
Test area load5 kg10 kgCustomized
Outside dimensions (W x H x D)1230 x 1830 x 12701380 x 1980 x 1370Customized
Weight800kg1100kgN/A

 

Utility requirements

 

Allowable ambient conditions+5~30°C
Power supplyAC380V, 50/60Hz, three phase , 30A
Cooling water supply pressure*602~0.4Mpa
Cooling water supply rate*68m³ /h
Operating cooling water temp. range+18 to 23 °C
Noise Level70 dB or lower

 

 

Notes:

 

1. If the high-temp exposure range lower limit + 60°C is required or the low temp exposure range lower limit -60°C, please select the “ambient-temperature exposure” option

2. If the temp fluctuation need to below ±1.8°C please select the “Low temp fluctuation package”

3. Temperature heat-up/pull down time are applicable only during independent chamber operation

4. If the automatically operated sliding door required, please select the “Automatically door package”

5. Air-cooled condenser / Water-cooled condenser both available

 

6. Apply on water-cooled condenser only

 

Safety Devices of Hot and Cold Temperature Shock Simulate Test Machine:

1. Hot chamber overheat protection switch

2. Cold chamber overheat protection switch

3. Air circulator overload alarm

4. Refrigerator high/low pressure protector

5. Compressor temperature switch

6. Air pressure switch

7. Fuse

8. Water suspension relay ( water-cooled specification only)

9. Compressor circuit breaker

10. Heater circuit breaker

11. Test area overheat/overcool protector

12. Air purge valve

 

 

Control

 

(Color LCD interactive touch-screen system)

 

Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, and trend graph displays.

 

SettingInteractive key input by touch panel
DisplayLCD (5.7 inches)
Temperature control function

Test area: exposure temp.

Hot chamber: pre-heating temp.

Cold chamber: pre-cooling temp.

PID control
Preset temperature range

High temperature: 60 to200’C

Low temperature: -78 to 0’C

Setting resolution1’C
InputThermocouple type T (Copper/Copper-Nickel)
Setting and indication ranges

Preset time: 0 min. to 99 hours and 59 min.

Preset cycle: 1 to 9,999 cycles

Accessory function

Timer preset

Overheat/ overcool protection

Power failure/ recovery selection

Temperature recovery time setting

Program memory

Automatic power shut-off

Programmed time display

Test completion mode selection

Trend graph

Alarm history display

Sensor calibration

RS-232/ USB communication

 

 

 

 