China Flammability Testing Equipment manufacturer
DONGGUAN YUYANG INSTRUMENT CO., LTD
8
Home > Products > Vertical Flammability Tester >

Automatic Vertical Fire Testing Equipment , Flammability Burning Testing Machine UL 1666

Automatic Vertical Fire Testing Equipment , Flammability Burning Testing Machine UL 1666

Brand Name YUYANG
Model Number YY201
Certification UL1666, UL1581
Place of Origin China
Minimum Order Quantity 1 set
Price Negotiation
Payment Terms T/T, L/C, Western Union
Supply Ability 2 sets per month
Delivery Time 12~15 work days
Packaging Details Plywood Case
Power Electric
Product Name Vertical Fire Testing Machine
U-type pressure gauge 0-12PA
External dimensions 7.12M high x1.3M wide x2.5M long
Detailed Product Description

 

 

Automatical UL1666 Cable Shaft Pipe Vertical Flammability Burning Testing Machine

 

 

Description:

 

UL1666 Cable Shaft Pipe Vertical Burning Testing Machine is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. The device complies with UL1581-2001(1060 FT1, 1061, 1080VW-1, 1090, 1100FT2) standards-related requirements designed. Applicable to the single wire and cable, and soft-line horizontal , vertical combustion test. Burning time and burning the number of adjustable, can be automatic / manual, vertical / horizontal switching, gas pressure, flow adjustable and equipped with flame temperature recognition device.
Includes: Flame height gauge and 100% absorbent cotton

 

 

Standards:

 

UL1666<<Test for flame propagation height of electrical and optical-fiber cables installed vertically in shafts>>

ANSI/ASTM D 5207 & UL 1581, ANSI/ASTM D 5025

 

 

Specifications:

 

Test chamber:

1. U-type pressure gauge: measuring chamber pressure maintained at 0-12PA;

2. Hygrometer: measuring chamber temperature and humidity;

3. The structure of the chamber: the overall structure of the concrete wall by the brick, the first layer is 1.22M, the second layer is 3.66M, the top is 2.24M. External dimensions: 7.12M high x1.3M wide x2.5M long;

4. The wall structure is a density of 106lb / ft3 (1698kd / m3) of concrete, the thermal conductivity (k) at 21.1 ℃ for the 0.38Btu (0.055W / mk);

5. The first and second layer by the 203mm thick ordinary weight of the cement composition.Roof is made of wall to ensure its tightness;

6. The measuring hole in the second layer must be above the vertical hole of the first layer measuring hole (305mm by 610mm), each hole is 203mm behind the box and 102mm from the side of the box.

 

Ignition device:

 

1. It consists of a 1 / 2inch steel pipe, a 1 / 2inch elbow and a steel ignition dispersion disc.

2. Install a propane flow meter where the gas is injected

 

Fan: Exhaust fan and anemometer are installed at the test box outlet.

Combustion gas source: The gas supplied to the igniter must be CP-grade propane and provide 2500 Btu of heat per cubic foot.

Exhaust Fans and Conveying Tubes: Steel ducts are installed in the center of the top of the test chamber, and the exhaust fan is connected to the duct.

Data acquisition system: The PLC and computer are used to collect and record the air velocity at the inlet and the temperature of the thermocouple in the second hole every 5 seconds.

 

 

Product Tags: vertical flammability chamber   fire resistance test furnace  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: DONGGUAN YUYANG INSTRUMENT CO., LTD
Subject:
Message:
Characters Remaining: (80/3000)