Ductile Cast Iron Made UL/FM/NFPA20 Certification Centrifugal Fire
Pump For Firefighting Application
Horizontal Split Case:
Horizontal split case pumps are the most common type of fire pump.
These pumps are specifically designed and tested for fire service
applications where reliability of performance is of vital
importance. Split case pumps are characterized by: • Easy access to
all working parts; • Rugged construction; • Liberal water passages;
and • Efficient operation. Split case fire pumps are specified when
the source of water is located above the surface of the ground and
provides a positive suction pressure to the pump at any performance
point. Single-stage or multistage pumps are available dependent
upon discharge pressure requirements. Aurora split case fire pumps
are built per the rigid standards of NFPA 20 and are listed by
Underwriters Laboratories (UL) and approved by Factory Mutual (FM).
Available in a broad range of operating pressures and flows from a
minimum of 500 GPM, NM split case pumps can be driven by either an
electric motor or diesel engine. NM’s UL-Listed, FM-Approved fire
pump packages also include the system controller, with a full range
of options and accessories available to complete the NFPA-compliant
fire pump package.
Application:
Industrial fields: All petroleum, petrochemical, chemical, oil
fields, pipelines bureaus, oil repositories, oil terminals, oil
refineries, offshore platforms, etc.; National grain storages,
thermal power plants, steel plants, shipyards, paper mills, etc.;
Commercial Field: five-star hotels, hospitals, schools,
supermarkets, office buildings, large-scale commercial complex,
highway tunnels, subway stations, railway stations, airports;
Fire-fighting Engineering Companies;
Performance Ranges:
UL: | Q: 500-4000GPM | H:100-190PSI |
FM: | Q: 500-4000GPM | H:100-190PSI |
CCCF: | Q:20-500L/S | H:0.42-2.0Mpa |
NFPA20: | Q: 300-8000GPM | H:60-300PSI |
Each pump shall have a circulation relief valve listed for the fire
pump service installed and set below the shutoff pressure at
minimum expected suction pressure. Exception: This rule shall not
apply to engine-driven pumps for which engine cooling water is
taken from the pump discharge.
Product Type:
Diesel engine driven fire pump sets with air cooling & water
cooling
NFPA20 Package
Advantage:
- NM Fire is the firt member of NFPA from Chinese pump manufacturers.
The production of fire pump groups is strictly in accordance with
NFPA20, production process and performance testing also meet the
requirement of ISO9001, some kinds of products have got APSAD
(France), UL,FM and CCCF certificates.
- We are the only enterprise in China that obtained not only UL and
FM certificates, but CCCF as well, also the firt company in the
world who was authorized by UL CCIC as witness testing center for
both fire pump and fire fighting engines
Service:
| 1. To supply high-quality products with reasonable prices in food
additive industry. |
| 2. To follow orders and arrange shipping in time, providing
complete documents |
| for Customs clearance according to different export policies in
different countries. |