IEC 61008 Plastic PA66 2P 4P RCCB Circuit Breaker
|
IEC 61008 ELCB, RCCB, RCD 2P,4P F360 series Residual Current Circuit Breaker electrical or magnetic type A or AC model
F360 series residual current circuit breaker is in conformity with the
standards of IEC61008.It can cut off the fault circuit immediately
on the occasion of shock hazard or earth leakage of trunkline.Thus
it is suitable to avoid the shock hazard and fire caused by earth
leakage.It can be used in circuits up to single phase 240V,three
phase 415V,50 or 60Hz. Product Description This series Residual Current Circuit Breaker is applicable to
electric circuits with rated voltage 230/400V AC, frequency 50/60Hz
and rated current up to 80Amp. 1. Rated sensitivity up to 30mA could be used as supplementary protecting device in case other protecting device fails its protection against electric shock. 2. This series RCCB designed for household installation and other similar application, is for non-professional operation, and no maintenance is required. 3. This series RCCB provides no protection against electric shock resulted from direct contacts of both protected lines,or leakage current between these two lines. 4. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side. 5. Satisfying conditions and applications as mentioned above, RCCB with °∞ON-OFF°± indicating device is considered suitable for isolation function.
Technical Data
1. Provides protection against earth fault/leakage current and function of isolation. 2. High short-circuit current withstand capacity. 3. Applicable to terminal and pin/fork type busbar connection. 4. Equipped with finger protected connection terminals. 5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity. 6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Residual tripping characteristicsType AC For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.Type A Type S
|
||||||||||||||||||||||
Product Tags: 4P RCCB Circuit Breaker PA66 RCCB Circuit Breaker IEC 61008 Residual Circuit Breaker |
![]() |
Sontuoec 6KA RCCB Circuit Breaker 2P 400V AC 16A Electrical Type |
![]() |
B Type Rccb Residual Current Circuit Breaker Electro Magnetic For Electric Vehicle |
![]() |
Fixed Red Copper Texture RCCB Circuit Breaker IP20 Protection |
![]() |
2P 4P 6KA 100 Amp RCCB Circuit Breaker Isolation Switching IEC61008 |
![]() |
B Type RCCB Residual Current Circuit Breaker Recharge Station Protection |
![]() |
63A 2P Magnetic Type Rccb Circuit Breaker For High Rise Building |