Zero Auto Tracking Dc 24V Guide Rail Weighing / Force
Measuring Led Control With Rs232 Main Menu | Second Menu | F6.FAC | Factory Adjustment | Special for manufacturer. | -SPAn- | 【mV】Exfactory Span Adjustment: Use standard weighing test equipment
to adjust the weighing signal interface for normalizing Span
Coefficient to 1. | | -AdtS- | Weighing Signal Linearity Test. | | -AVZF- | AO [0~20mA] Zero/Full Adjustment. VO [0~10V] Zero/Full Adjustment. | | -AVtS- | AO [0~20mA] Linearity Test. VO [0~10V] Linearity Test. | | -dIdo- | DI/DO Input&Output Test. | | -dEFU- | RAM Reset: Reset to factory defaults. | | -dStS- | Display/DO Reliability Test. | | F7.InF | Product Information | Only for query. | | --VEr- | Version No. | | --Sn-- | Serial No. | | -dAtE- | Exfactory Date. | | -HArd- | Hardware Configuration. | |
Dc 24V Guide Rail Weighing / Force Measuring Led Control Module
With Rs232 and Rs485 Main Features: - Applications: Weight/Force Display, Peak Value
Detection&Display Holding, Auto Weight-checking, Setpoint DO
Output and AO/Digit Transmission.
- EMC design with high anti-jamming capability, suitable for
industrial environment.
- 32-bit ARM CPU with 48MHz clock & high arithmetic speed.
- 6+6 Red LED digital tubes for English character and digit display.
- 4-key English keypad for Menu&Shortcut mode operation.
- 24-bit High-precision and high-speed ∑-△A/D conversion module with
1/1,000,000 internal resolution and max. sampling frequency 3200Hz.
- Special anti-vibration digital filtering algorithm for ensuring the
weighing stability and accuracy when there is strong vibration on
the load receptor, and the rapid response capability when the
weight signal changes.
- Max. Connection Quantity: 8 Loadcells (350Ω).
- Zero Upon Power Up, Zero Auto-tracking, Manual/Auto Zero and Zero
Calibration available.
- Load Calibration, Data Calibration, Segmenting Span Correction and
Segmenting Weight Calculation available.
- Auto-locking, Key-locking, Key-unlocking, Digital
Setting&Calibration and I/O Testing functions available.
- 3 Definable normally open switch inputs [DI] and 3 definable
normally open transistor switch outputs [DO].
- 1 Optional&definable current signal output [AO: 0~20mA].
- 1 Optional&definable voltage signal output [VO: 0~10V].
- RS232, optional RS485 and CANBUS communication ports for connecting
Host IPC/PLC and LED Remote Display.
- With the multitasking mode, the weighing/force measuring process,
alarm output and signal transmission will not be interrupted by
parameter setting and the other operations.
Keypad Operation
Key Name | Function | Description | 【■】 | 【MENU】 | Enter Main Menu / Exit. | 【LOCK】* | Key-locking / Key-unlocking. | 【►】 | 【►】 | Cursor shifts right. Display the previous interface or option. | 【ZERO】* | Manual Zero without Power-down Protection. | 【▲】 | 【▲】 | Display the next interface or option. Digit input: +1 ( 0~9 loop). | 【SET】* | Setpoint Parameters Setting. | 【8】 | 【ENT】 | Enter / Save / Clear Alarm. | 【CLS】* | Clear Screen [Clear the display value of Peak Hold Value and
Weight-checking Value]. |
User Interface Diagram
Installation
Main Menu Main Menu | Second Menu | Sign | Function | Sign | Description | F1.SEt | Parameter Setting | -SCAL | Scale parameters setting. | -CALP- | Calibration parameters setting. | -SEtP- | Setpoint parameters setting. | -SErP- | Communication parameters setting. | -dISP- | User interface parameters setting. | F2.CAL | System Calibration | -ZEro- | Zero Calibration without loading on the weigher to correct Zero
Value. | -dAtA- | Data Calibration: Input the specification parameter values of
loadcell according to the actual configuration of the weighing
system to correct Span Coefficient. If there is no access to get
the specification parameter values for Data Calibration, then it’s
necessary to do Load Calibration. | -LoAd- | Load Calibration: After doing Data Calibration, if there are
conditions for Load Calibration, do Load Calibration with loading
standard weight on the weigher to correct Span Coefficient further
for higher weighing accuracy. | -SEgC- | Segmenting Span Correction: After doing Zero Calibration and Load
Calibration [or Data Calibration], it’s allowed to do Segmenting
Span Correction with loading standard weight on the weigher by 10
Correction Points to get Span Correction Ratio of 10 linearity
segments for higher weighing accuracy. | F3.rEC | | | Unused. | F4.CLn | | | Clear Screen: Clear the display value of Peak Hold Value and
Weight-checking Value. | F5.Loc | Key-locker | -oPEn- | Key-unlocking. | -Locc- | Key-locking. | -PASS- | Password Set. Exfactory Passwords: - Operator Password: 000.
- Administrator Password: 001.
|
|