China Weighing Indicator Controller manufacturer
CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID
CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID. BEING SUPER IN METER BEING PERFECT IN SERVICE
8
Home > Products > Belt Scale Controller >

Panel Mount Belt Scale Controller High Accuracy Flow Control Loadcell Weighing Indicator

Panel Mount Belt Scale Controller High Accuracy Flow Control Loadcell Weighing Indicator

Brand Name Supmeter
Model Number BST100-E21
Certification CE
Place of Origin China
Minimum Order Quantity 1pcs
Price 238-430usd/pcs
Payment Terms T/T, Western Union
Supply Ability 1000pcs/month
Delivery Time 3-10 working days
Packaging Details 1pcs/box
Installation Panel Mounted
power DC24V
DI 3
AO 4-20Ma
Loadcell connect 8 Loadcells
Detailed Product Description

DC24V High Accuracy Of flow control Loadcell Belt Scale Weighing Indicator With 3 DI and 4 DO

 

Main Features:

1 ‘Flow Set’ Analog Input [AI]: 4~20mA, 0.05%FS.

2. COM1: Optional RS232/RS485/RS422/Profibus-DP/Ethernet.

3. COM2: RS232.

4. Connect Host IPC, Remote Display, Printer&Wireless Module.

5. Outline Size [W×H×D]: 164 × 86 × 193 mm.

6. Panel Cut-out Size [W×H]: 153 × 77 mm.

​7. Accuracy of Flow Control: 0.5%~1.0%.

 

 

Main MenuSecond MenuDescription
F1 Setting1 Scale[Basic]Basic scale parameters setting.
 1+Scale[Extra]Extra scale parameters setting.
 2 Control[Basic]Basic feeding control parameters setting.
 2+Control[Extra]Extra feeding and batching control parameters setting.
 3 FlowFlow parameters setting.
 4 SpeedSpeed parameters setting.
 5 LoadLoad parameters setting.
 6 Save/PrintWeight record parameters setting.
 7 Comm. PortCommunication port parameters setting.
 8 I/OInput&output parameters setting.
 9 DisplayDisplay and operation interface parameters setting.
 10 Date/TimeDate/Time parameters setting.
F2 Calibration1 Zero Cal.Zero Calibration without loading for correcting Zero Value.
 2 Span Cal. Dyn.Dynamic Span Calibration with loading measured materials or Poise Weights for correcting Span Coefficient.
 3 Span Cal.Stat1Static Span Calibration with a measured chain weight as a continuous and steady load on the running belt weigher for correcting Span Coefficient.
 4 Span Cal.Stat2Static Span Calibration with a measured Hanging Weight as a steady load on the running belt weigher for correcting Span Coefficient.
 5 Span Cor. Seg.Segmenting Span Correction. After doing Dynamic or Static Span Calibration, further corrections for 3 [AD Value: 0~60000] linear segments are optional for correcting Correction Coefficient 1~3.
 6 Speed Cal.

Speed Coefficient Calibration.

Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Speed Coefficient.

 7 Length Cal.

Belt Length Calibration.

Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Belt Length.

 

 

Model Wall-mounting Installation

 

 

 

Main Menu

Second MenuDescription
F3 Weight Record Query and print Weight Records.
F4 Data Clearing1 Clear Screen

Clear Totalized Weight and Totalized Weight Pulse Count.

But Totalized Weight of Current Shift will not be cleared, so this operation has no effect on recording of weight per shift.

 2 Clear Weight

Clear Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift.

The cleared value of Totalized Weight of Current Shift will not be recorded.

 3 Clear Records

Clear History Records of Totalized Weight.

But Current Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift will not be cleared.

F5 Security1 Auto-lockingIf there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory Adj.’, the controller will lock the keypad and return to ‘Main Display Interface’ automatically.
 2 Key-lockingLocking keypad.
 3 Key-unlockingUnlocking keypad.
 4 Password SetExfactory Password: 000001.
 5 RAM ResetRestore to factory defaults.
F6 Factory Adj. Special for manufacturer.
F7 Product Info.Only for query.
 1 Version No.Version No.
 2 Serial No.Serial No.
 3 Exfactory DateExfactory Date.
 4 Audit CounterAudit Trail Counter [0~99999999] for Scale parameter’s modification.
 5 Auth. CodeAuthorization Code.

 

Delivery

 

Product Tags: belt weigher indicator   digital indicator with remote display  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID
Subject:
Message:
Characters Remaining: (80/3000)