Main Menu | Second Menu | Description |
F1 Setting | 1 Scale[Basic] | Basic scale parameters setting. |
| 1+Scale[Extra] | Extra scale parameters setting. |
| 2 Control[Basic] | Basic feeding control parameters setting. |
| 2+Control[Extra] | Extra feeding and batching control parameters setting. |
| 3 Flow | Flow parameters setting. |
| 4 Speed | Speed parameters setting. |
| 5 Load | Load parameters setting. |
| 6 Save/Print | Weight record parameters setting. |
| 7 Comm. Port | Communication port parameters setting. |
| 8 I/O | Input&output parameters setting. |
| 9 Display | Display and operation interface parameters setting. |
| 10 Date/Time | Date/Time parameters setting. |
F2 Calibration | 1 Zero Cal. | Zero Calibration without loading for correcting Zero Value. |
| 2 Span Cal. Dyn. | Dynamic Span Calibration with loading measured materials or Poise
Weights for correcting Span Coefficient. |
| 3 Span Cal.Stat1 | Static Span Calibration with a measured chain weight as a
continuous and steady load on the running belt weigher for
correcting Span Coefficient. |
| 4 Span Cal.Stat2 | Static Span Calibration with a measured Hanging Weight as a steady
load on the running belt weigher for correcting Span Coefficient. |
| 5 Span Cor. Seg. | Segmenting Span Correction. After doing Dynamic or Static Span
Calibration, further corrections for 3 [AD Value: 0~60000] linear
segments are optional for correcting Correction Coefficient 1~3. |
| 6 Speed Cal. | Speed Coefficient Calibration. Keep the belt weigher running at a constant speed. After the
running time of a revolution being measured with using a stopwatch,
do this operation for correcting Speed Coefficient. |
| 7 Length Cal. | Belt Length Calibration. Keep the belt weigher running at a constant speed. After the
running time of a revolution being measured with using a stopwatch,
do this operation for correcting Belt Length. |