Transmitter Load Cell Indicator Controller With 4-20mA Analog Output
|
Transmitter Load Cell Indicator controller with 4-20mA Analog Output
Main Features: 1. Applications: Weight/Force Display, Peak Value Detection&Display Holding, Setpoint DO Output and AO/Digit Transmission. 2. 4 Optional Setpoint DO Output Modes: Weight Limit DO Alarm Mode, Weight Increment DO Output Mode, Weight Decrement DO Output Mode and Weight Section DO Output Mode. 3. EMC design with high anti-jamming capability, suitable for industrial environment. 4. 32-bit ARM CPU with 48MHz clock & higher arithmetic speed. 5. 5 Red LED digital tubes for English character and digit display. 6. 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 1280Hz.
Technical Specification 1. Executing Standard 2. CMC GB/T 7724-2008PRC National Standard. 3. OMIL R76: 2006International Recommendation. 4. Accuracy Grade: III. 5. Verification Accuracy: 0.03%. 6. Static Weighing Accuracy: 0.2%~0.5%.
Display 1. 5 Red LED digital tubes for English character and digit display. 2. Weight Display Range: -9,999~+99,999. 3. Scale Capacity: Setting Range 1~99,999. 4. Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500. 5. Display Resolution: 1/50,000. 6. Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000. 7. Display Refreshing Time: Setting Range 0.01~1.00s.
Kaypad 1. 4-key keypad for Menu&Shortcut mode operation. 2. Weighing Signal Interface 3. Excitation Voltage / Max. Current 1: DC5V/120mA for 8-350Ω loadcells. 4. Excitation Voltage / Max. Current 2: DC12V/100mA for weighing transmitter. 5. Optional weighing input signal mV, V and mA for connecting ‘【mV】Output Type Loadcell’, ‘【V】Voltage Output Type Weighing Transmitter’ and ‘【mA】 Current Output Type Weighing Transmitter’. 6.【mV】Signal Input Range: 0~19.5mV [Output Sensitivity of Loadcell: 1.0~3.5mV/V]. 7.【V】Signal Input Range: 0~2.5V, 0~5V, 0~10V. 8.【mA】Signal Input Range: 0~20mA. 9. 24-bit ∑-△ADC with internal resolution 1/1,000,000. 10. Sampling Frequency: 1280Hz.
Keypad Operation If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
*: Keep the key pressed for 2 seconds.
*: Keep the key pressed for 2 seconds.
Installation
Operation Procedure
Delivery |
||||||||||||||||||||||||||||||||||||||||||
Product Tags: electronic weight indicator digital load controller |
![]() |
Overload Protection Electronic Weighing Indicator Low / High Limit Output |
![]() |
Transmission Type Weighing Indicator Speed Sensor For Belt Weigher Belt Weighfeeder |
![]() |
Electric Conveyor Belt Speed Sensor Inductance Sensor For Belt Scale Use |
![]() |
Belt Scale Electric Conveyor Speed Sensor For Weighing Indica , Long Life |
![]() |
IP67 Speed Sensor For Conveyor Belt Scale , Belt Weigher Conveyor Speed Sensor |
![]() |
Durable Mini 3- D /3- Channels Force Measuring Controller BST106-B60R( F ) |