Mini Weighing Force Measuring Controller Digital Weight Indicator
With Weight/Force Display Main Features: - Applications: Weight/Force Display, Peak Value
Detection&Display Holding, Setpoint DO Output and AO/Digit
Transmission.
- 4 Optional Setpoint DO Output Modes: Weight Limit DO Alarm Mode,
Weight Increment DO Output Mode, Weight Decrement DO Output Mode
and Weight Section DO Output Mode.
- EMC design with high anti-jamming capability, suitable for
industrial environment.
- 32-bit ARM CPU with 48MHz clock & higher arithmetic speed.
- 5 Red LED digital tubes for English character and digit display.
- Menu&Shortcut mode operation.
- 24-bit High-precision and high-speed ∑-△A/D conversion module with
1/1,000,000 internal resolution and sampling frequency 1280Hz.
- Special anti-vibration digital filtering algorithm for ensuring the
weighing stability and accuracy when there is strong vibration on
the load receptor, and the rapid response capability when the
weight signal changes.
- Optional weighing input signal mV, V and mA for connecting
‘【mV】Output Type Loadcell’, ‘【V】Voltage Output Type Weighing
Transmitter’ and ‘【mA】Current Output Type Weighing Transmitter’.
- Auto Zero Initial Calibration after Power-on, Auto Zero Tracking,
Zero Fine Adjustment, Zero Calibration and Load Calibration
functions available.
- Optional Data Calibration, Segmenting Span Correction and
Segmenting Weight Calculation functions.
- Auto-locking, Key-locking, Key-unlocking, Digital
Setting&Calibration and I/O Testing functions available.
- 2 Relay switches with normally open and normally closed contacts
for outputting upper limit and lower limit alarm signals.
- 1 Optional and definable analog signal output [AO: 0~20mA].
- Optional RS232 and RS485 communication ports for connecting Host
IPC/PLC and LED Remote Display.
- With the multitasking mode, the processes of weighing, alarm output
and signal transmission will not be interrupted by parameter
setting and the other operations.
Technical Specification- CMC GB/T 7724-2008PRC National Standard.
- OMIL R76: 2006International Recommendation.
- Accuracy Grade: III.
- Verification Accuracy: 0.03%.
- Static Weighing Accuracy: 0.2%~0.5%.
- 5 Red LED digital tubes for English character and digit display.
- Weight Display Range: -9,999~+99,999.
- Scale Capacity: Setting Range 1~99,999.
- Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
- Display Resolution: 1/50,000.
- Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
- Display Refreshing Time: Setting Range 0.01~1.00s.
- 4-key keypad for Menu&Shortcut mode operation.
- Weighing Signal Interface
- Excitation Voltage / Max. Current 1: DC5V/120mA for 8-350Ω
loadcells.
- Excitation Voltage / Max. Current 2: DC12V/100mA for weighing
transmitter.
- Optional weighing input signal mV, V and mA for connecting
‘【mV】Output Type Loadcell’, ‘【V】Voltage Output Type Weighing
Transmitter’ and ‘【mA】 Current Output Type Weighing Transmitter’.
- 【mV】Signal Input Range: 0~19.5mV [Output Sensitivity of Loadcell:
1.0~3.5mV/V].
- 【V】Signal Input Range: 0~2.5V, 0~5V, 0~10V.
- 【mA】Signal Input Range: 0~20mA.
- 24-bit ∑-△ADC with internal resolution 1/1,000,000.
- Sampling Frequency: 1280Hz.
- Special anti-vibration digital filtering algorithm.
- Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
- Gain Drift: ±5ppm/℃.
- Non-linearity: 0.005%FS.
- Switch&Analog Signal Interface
- 2 Relay switches with normally open and normally closed contacts
for outputting upper limit and lower limit alarm signals.
- Contact Capacity of Relay Switch: AC250V/DC24V, 1A.
- 1 Optional&Definable Analog Signal Output [AO]: 0~20mA,
Non-linearity: 0.05%FS.
Digital Communication Interface
- COM1: Optional RS232.
- COM2: Optional RS485.
- Connectable: Host IPC/PLC and LED Remote Display.
- Operating Voltage: DC24V±20%.
- Max. Power Consumption: 5W.
- Outline Size: 107×60×100mm [W×H×D].
- Panel Cut-out Size: 94×47mm [W×H].
- Operating Temperature: -25℃ to +45℃.
- Storage Temperature: -30℃ to +60℃.
- Relative Humidity: Max. 85%RH.
- Protection Level of Front Panel: IP65.
- Weight: Approx. 0.3kg.
Keypad OperationIf there is not any keypad operation in one minute and it’s not in
the processes of ‘F2 System Calibration’ & ‘F6 Factory
Adjustment’, the controller will return to ‘Main Display Interface’
automatically. Menu Operation | Key Name | Description | 【■】 | Enter Main Menu / Exit. | 【8】 | Enter / Save / Alarm Acknowledge. | 【►】 | Cursor shifts right. Display the previous option. | 【▲】 | Display the next interface or option. Digit input: +1 ( 0~9 loop). |
Quick Operation Mode A Parameter [904]= ‘0. dE’ [Default Set] | Key Name | Description | 【■】* | - Key-locking.
- Key-unlocking.
| 【►】 (【SET】) | Setpoint parameters setting. | 【►】* (【ZERO】) (【→0←】) | - [-ZEro]: Zero Calibration with Power-down Protection and Clearing
Tare Weight.
- [≡ZEro]: Zero Fine Adjustment without Power-down Protection and
without Clearing Tare Weight.
- The controller will switch to Gross Weight display.
| 【▲】* (【TARE】) (【→T←】) | - [≡tArE]: Manual Tare without Power-down Protection.
- [-PStr]: Preset Tare Weight with Power-down Protection.
- [-rStr]: Clear Tare Weight with Power-down Protection.
- The controller will switch to Net Weight display.
| 【8】 (【G/N】) | Gross Weight / Net Weight / Net Weight Peak Value display switch. | 【8】* (【CLS】) | - [-CLS] : Clear Screen [Clear the display value of Peak Value].
|
Quick Operation Mode B Parameter [904]= ‘1. Au’ | Key Name | Description | 【■】* | - Key-locking (Excluding Key【ZERO】&【TARE】).
- Key-unlocking.
| 【►】 (【ZERO】) (【→0←】) | - Zero Calibration with Power-down Protection and Clearing Tare
Weight.
- The controller will switch to Gross Weight display.
| 【▲】 (【TARE】) (【→T←】) | - Manual Tare with Power-down Protection.
- The controller will switch to Net Weight display.
| 【8】 (【G/N】) | Gross Weight / Net Weight / Net Weight Peak Value display switch. | 【8】* (【CLS】) | - [-CLS] : Clear Screen [Clear the display value of Peak Value].
|
|