China Water Quality Sensor manufacturer
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
8
Home > Products > Electromagnetic Flow Meter >

Proline Prowirl D 200 vortex flowmeter

Proline Prowirl D 200 vortex flowmeter

Brand Name Endress+Hauser
Certification CE
Place of Origin Switzerland
Minimum Order Quantity 1PCS
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Model Number Proline Prowirl D 200
Wetted materials Measuring tube: 1.4408 (CF3M)
Measured variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. process pressure PN 40, Class 300, 20K
Sensor housing material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) AlSi10Mg, coated; 1.4404 (316L)
Detailed Product Description

"Specs at a glance
Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %

Measuring range
Liquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

Max. process pressure
PN 40, Class 300, 20K

Wetted materials
Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)"    "Field of application
The Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. With genuine loop-powered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)

For all basic applications and for 1-to-1 replacement of orifice plates.

Device properties

Face-to-face length of 65 mm (2.56 in)

No flanges

Low weight

Display module with data transfer function

Robust dual-compartment housing

Plant safety: worldwide approvals (SIL, Haz. area)"    "Benefits
Integrated temperature measurement for mass/energy flow of saturated steam

Easy alignment of the sensor – included centering rings

High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer

Long-term stability – robust drift-free capacitive sensor

Convenient device wiring – separate connection compartment

Safe operation – no need to open the device due to display with touch control, background lighting

Integrated verification – Heartbeat Technology"    "Measuring principle
Vortex

Product headline
Cost-effective wafer flowmeter, available as compact or remote version.
Integrated temperature measurement for mass/energy flow of saturated steam.
For all basic applications and for 1-to-1 replacement of orifice plates.

Sensor features
Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor.
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.

Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

Nominal diameter range
DN 15 to 150 (½ to 6"")

Wetted materials
Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)

Measured variables
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %

Measuring range
Liquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

Max. process pressure
PN 40, Class 300, 20K

Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

Ambient temperature range
Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F)

Sensor housing material
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter housing material
AlSi10Mg, coated; 1.4404 (316L)

Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)

Inputs
Current input 4‐20 mA (passive)

Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET over Ethernet-APL, Modbus TCP over Ethernet-APL

Power supply
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous area approvals
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

Product safety
CE, C-TICK, EAC

Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine approvals and certificates
ABS, LR, BV, DNV, CCS

Pressure approvals and certificates
PED, CRN

Material certificates
3.1 material
NACE MR0175/MR0103, PMI (on request)"