China Fluid Level Meter manufacturer
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
7
Home > Products > Gas Detector Sensor >

Online Dust Concentration Tester KGD-OPM-212

Online Dust Concentration Tester KGD-OPM-212

Brand Name KACISE
Model Number KGD-OPM-212
Certification CE
Place of Origin CHINA
Minimum Order Quantity 1PCS
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Power-on Stabilization Time ≤8 seconds
Data Refresh Frequency 1 second
Operating Conditions -30℃ to 70℃; 0 to 95% Relative Humidity (RH) (non-condensing)
Storage Conditions -40℃ to 85℃, 0 to 95% Relative Humidity (RH) (non-condensing)
Operating Voltage DC 12V
Average Operating Current ≤4.5A
Detailed Product Description

Online Dust Concentration Tester KGD-OPM-212

Product Introduction

The KGD-OPM-212 Online Dust Concentration Tester adopts the principle of optical scattering. It can accurately detect and calculate the number of suspended particulate matters of different particle sizes in the air per unit volume. It is equipped with KACISE's brand-new intelligent dust source identification technology and combined with an air pump with a stable flow rate, enabling the real-time detection and output of the mass concentrations of particulate matters PM1.0, PM2.5, PM10, and TSP.

Product Features

  • Brand-new intelligent dust source identification technology
  • Industrial-grade laser, with high reliability
  • Constant current sampling structure to ensure a constant sampling flow rate
  • Real-time measurement of the mass concentrations of PM1.0, PM2.5, PM10, and TSP, and the detection data is updated once every second
  • Operates within a wide temperature range for greater stability

Technical Parameters

Detection Range0~30mg/m³
Measurement Accuracy of PM1.0 and PM2.5≤100μg/m³: ±10μg/m³; 100~1000μg/m³: ±10% of the reading
Measurement Accuracy of PM10≤100μg/m³: ±15μg/m³; 100~1000μg/m³: ±15% of the reading
Measurement Accuracy of TSP≤100μg/m³: ±20μg/m³; 100~1000μg/m³: ±20% of the reading (Using the traceability system benchmarked with Wuhan National Station. If there are differences in the measured values in other regions, the coefficient calibration is required according to the local distribution of dust particulate matters)
Power-on Stabilization Time≤8 seconds
Data Refresh Frequency1 second
Operating Conditions-30℃ to 70℃; 0 to 95% Relative Humidity (RH) (non-condensing)
Storage Conditions-40℃ to 85℃, 0 to 95% Relative Humidity (RH) (non-condensing)
Operating VoltageDC 12V
Average Operating Current≤4.5A
Communication InterfaceRS485 interface
Sampling Flow Rate1L/min (Default flow rate, which can be customized by customers)

 

Product Tags: Online Dust Concentration Tester   KGD-OPM-212 Dust Concentration Tester   KGD-OPM-212 Online Dust Concentration Tester  